Monte Carlo simulation of dose distributions from a synchrotron-produced microplanar beam array using the EGS4 code system4
- 25 August 2000
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (9) , 2497-2508
Abstract
Microbeam therapy is established as a general concept for brain tumour treatment. A synchrotron based x-ray source was chosen for experimental research into microbeam therapy, and therefore new simulations were essential for investigating the therapy parameters with a proper description of the synchrotron radiation characteristics. To design therapy parameters for tumour treatments, the newly upgraded LSCAT (Low energy SCATtering) package of the EGS4 Monte Carlo simulation code was adapted to develop an accurate self-written user code for calculating microbeam radiation dose profiles with a precision of 1 microm. LSCAT is highly suited to this purpose due to its ability to simulate low-energy x-ray transport with detailed photon interactions (including bound electron incoherent scattering functions, and linear polarized coherent scattering). The properties of the synchrotron x-ray microbeam, including its polarization, source spectrum and beam penumbra, were simulated by the new user codes. Two concentric spheres, an inner sphere, defined as a brain, and a surrounding sphere, defined as a skull, represented the phantom. The microbeam simulation was tested using a 3 x 3 cm array beam for small treatment areas and a 6 x 6 cm array for larger ones, with different therapy parameters, such as beam width and spacing. The results showed that the microbeam array retained an adequate peak-to-valley ratio, of five times at least, at tissue depths suitable for radiation therapy. Dose measurements taken at 1 microm resolution with an 'edge-on' MOSFET validated the basics of the user code for microplanar radiation therapy.Keywords
This publication has 14 references indexed in Scilit:
- MOSFET dosimetry of an X-ray microbeamIEEE Transactions on Nuclear Science, 1999
- Neuropathology of ablation of rat gliosarcomas and contiguous brain tissues using a microplanar beam of synchrotron-wiggler-generated X raysInternational Journal of Cancer, 1998
- Calculation of microplanar beam dose profiles in a tissue/lung/tissue phantomPhysics in Medicine & Biology, 1998
- Simultaneous macro and micro dosimetry with MOSFETsIEEE Transactions on Nuclear Science, 1996
- Compton scattering of 20- to 40-keV photonsPhysical Review A, 1995
- Implementation of linearly-polarized photon scattering into the EGS4 codeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993
- Inhibition of vascular endothelial growth factor-induced angiogenesis suppresses tumour growth in vivoNature, 1993
- PHOTON: A program for synchrotron radiation dose calculationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1988
- The calculation of scattering cross sections for polarized X-raysNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1986
- Synchrotron radiation as an absolute standard sourceNuclear Instruments and Methods, 1980