A Novel Stimulus to Improve Perimetric Sampling within the Macula in Patients with Glaucoma
Open Access
- 1 April 2021
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (4) , 374-383
Abstract
SIGNIFICANCE: Identifying glaucomatous damage to the macula has become important for diagnosing and managing patients with glaucoma. In this study, we presented an approach that provides better perimetric sampling for the macular region, by testing four locations, with a good structure‐function agreement. PURPOSE: We previously presented a basis for customizing perimetric locations within the macula. In this study, we aimed to improve perimetric sampling within the macula by presenting a stimulus at four locations, with maintaining a good structure‐function agreement. METHODS: We tested one eye each of 30 patients (aged 50 to 88 years). Patients were selected based on observed structural damage to the macula, whereas perimetric defect (using 24‐2) did not reflect the locations and extent of this damage. We used en face images to visualize retinal nerve fiber bundle defects. To measure perimetric sensitivities, we used a blob stimulus (standard deviation of 0.25°) at the 10‐2 locations. A perimetric defect for a location was defined as any value equal to or deeper than −4, −5, and −6 dB below the mean sensitivity for 37 age‐similar controls (aged 47 to 78 years). We also presented an elongated sinusoidal stimulus for 20 patients at four locations within the macula, in which we defined a perimetric defect as any value below the 2.5th percentile from controls. RESULTS: The −4, −5, and −6 dB criteria identified perimetric defects in 14, 13, and 11 patients, respectively. When testing with the elongated stimulus, 18 patients were identified with perimetric defect. The perimetric defects were consistent with the structural damage. CONCLUSIONS: The elongated stimulus showed a good structure‐function agreement with only four testing locations as compared with 68 locations used with the blob stimulus. This demonstrates a clinical potential for this new stimulus in the next generation of perimetry.Keywords
Funding Information
- National Eye Institute (EY024542)
This publication has 31 references indexed in Scilit:
- Simulated Visual Fields Produced from Macular RNFLT Data in Patients with GlaucomaCurrent Eye Research, 2013
- Blur‐Resistant Perimetric StimuliOptometry and Vision Science, 2013
- Assessment of macular function of glaucomatous eyes by multifocal electroretinogramsDocumenta Ophthalmologica, 2012
- Shadow Removal and Contrast Enhancement in Optical Coherence Tomography Images of the Human Optic Nerve HeadInvestigative Ophthalmology & Visual Science, 2011
- Responses of Primate Retinal Ganglion Cells to Perimetric StimuliInvestigative Ophthalmology & Visual Science, 2011
- Predicting Visual Function from the Measurements of Retinal Nerve Fiber Layer StructureInvestigative Ophthalmology & Visual Science, 2010
- Pulsar Perimetry in the Diagnosis of Early GlaucomaAmerican Journal of Ophthalmology, 2010
- Structural and functional assessment of the macular region in patients with glaucomaBritish Journal of Ophthalmology, 2006
- Linearity Can Account for the Similarity Among Conventional, Frequency‐Doubling, and Gabor‐Based Perimetric Tests in the Glaucomatous MaculaOptometry and Vision Science, 2006
- Threshold and Variability Properties of Matrix Frequency-Doubling Technology and Standard Automated Perimetry in GlaucomaInvestigative Ophthalmology & Visual Science, 2005