Continuous Hydrogen Sulfide Monitor Based on Positive Fluorescence Green Chemistry. Application to Geothermal Powerplant Environmental Impact Assessment
Open Access
- 29 April 2026
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (18) , 26993-27001
Abstract
Renewable geothermal sources can be used for base-load power generation. Prior environmental impact assessment is needed, however, for H2S emitted from wells and cooling towers. Detailed spatiotemporal H2S concentration data need continuous monitoring by sensitive and fieldable H2S analyzers. Fluorescein mercuric acetate (FMA), a toxic organomercuric reagent, has been a staple for H2S measurement. We report a reagent containing copper 8-hydroxyquinoline-5-sulfonic acid (HQS) complex and Zn2+. As HS– from sample air bearing H2S reacts with such a reagent, thiophilic copper forms the hydrosulfide, and the released HQS forms a fluorescent zinc chelate. An automated fieldable H2S analyzer based on this green chemistry, comprising a disposable gas scrubber with controlled liquid flow at 50 μL/min and a UV-laser based fluorescence detector, is reported. The instrument operates on a (4 min sample, 6 min zero) reporting the difference signal via a Raspberry Pi controller to the cloud every 10 min with a working range of 0.3 ppb (limit of detection) to >100 ppb. During each cycle a total of 0.8 L air and 1 mL aqueous solution containing 5 μmol NaOH, 10 μmol 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, 40 nmol HQS, and 20 nmol each of Cu and Zn are consumed with a total chemical cost < USD $0.01. Performance characteristics and data from a geothermal field are reported. It provides far superior sensitivity and time resolution than conventional impinger absorption and colorimetry. It should find wide use in geothermal environmental assessment and for monitoring oil drilling and storage sites, paper-pulp and sewage treatment facilities, livestock management, etc.Keywords
Funding Information
- New Energy and Industrial Technology Development Organization (JPNP21001)
- Japan Society for the Promotion of Science (23K28216)
This publication has 44 references indexed in Scilit:
- Atmospheric nitrogen oxides (NOx), hydrogen sulphide (H2S) and carbon monoxide (CO): Boon or Bane for plant metabolism and development?Environmental Pollution, 2025
- The role of sulfur in palladium transport and fractionation from platinum by hydrothermal fluidsGeochimica et Cosmochimica Acta, 2024
- Strategies to achieve a carbon neutral society: a reviewEnvironmental Chemistry Letters, 2022
- A new palladium complex as a dual fluorometric and colorimetric probe for rapid determination of sulfide anionJournal of Photochemistry and Photobiology A: Chemistry, 2021
- Membrane-based microchannel device for continuous quantitative extraction of dissolved free sulfide from water and from oilAnalytica Chimica Acta, 2012
- Fluorescent Probes for the Detection of Hydrogen Sulfide in Biological SystemsAngewandte Chemie International Edition, 2012
- A fluorescein-based fluorogenic and chromogenic chemodosimeter for the sensitive detection of sulfide anion in aqueous solutionAnalytica Chimica Acta, 2009
- Cu(II) complexation by “non-coordinating” N-2-hydroxyethylpiperazine-N′-2-ethanesulfonic acid (HEPES buffer)☆Journal of Inorganic Biochemistry, 2005
- Micro-gas analysis system μGAS comprising a microchannel scrubber and a micro-fluorescence detector for measurement of hydrogen sulfideAnalytica Chimica Acta, 2004
- Enhancement and quenching of fluorescence of metal chelates of 8-hydroxyquinoline-5-sulfonic acidMicrochimica Acta, 1986