Highly accelerated free-breathing real-time 2D flow imaging using compressed sensing and shared velocity encoding
- 2 September 2023
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 34 (3) , 1692-1703
Abstract
Objectives 2D real-time (RT) phase-contrast (PC) MRI is a promising alternative to conventional PC MRI, which overcomes problems due to irregular heartbeats or poor respiratory control. This study aims to evaluate a prototype compressed sensing (CS)-accelerated 2D RT-PC MRI technique with shared velocity encoding (SVE) for accurate beat-to-beat flow measurements. Methods The CS RT-PC technique was implemented using a single-shot fast RF-spoiled gradient echo with SVE by symmetric velocity encoding, and acquired with a temporal resolution of 51–56.5 ms in 1–5 heartbeats. Both aortic dissection phantom (n = 8) and volunteer (n = 7) studies were conducted using the prototype CS RT (CS, R = 8), the conventional (GRAPPA, R = 2), and the fully sampled PC sequences on a 3T clinical system. Flow parameters including peak velocity, peak flow rate, net flow rate, and maximum velocity were calculated to compare the performance between different methods using linear regression, intraclass correlation (ICC), and Bland–Altman analyses. Results Comparisons of the flow measurements at all locations in the phantoms demonstrated an excellent correlation (all R2 ≥ 0.93) and agreement (all ICC ≥ 0.97) with negligible means of differences. In healthy volunteers, a similarly good correlation (all R2 ≥ 0.80) and agreement (all ICC ≥ 0.90) were observed; however, CS RT slightly underestimated the maximum velocities and flow rates (~ 12%). Conclusion The highly accelerated CS RT-PC technique is feasible for the evaluation of flow patterns without requiring breath-holding, and it allows for rapid flow assessment in patients with arrhythmia or poor breath-hold capacity. Clinical relevance statement The free-breathing real-time flow MRI technique offers improved spatial and temporal resolutions, as well as the ability to image individual cardiac cycles, resulting in superior image quality compared to the conventional PC technique when imaging patients with arrhythmias, especially those with atrial fibrillation. Key Points • The highly accelerated prototype CS RT-PC MRI technique with improved temporal resolution by the concept of SVE is feasible for beat-to-beat flow evaluation without requiring breath-holding. • The results of the phantom and in vivo quantitative flow evaluation show the ability of the prototype CS RT-PC technique to obtain reliable flow measurements similarly to the conventional PC MRI. • With less than 12% underestimation, excellent agreements between the two techniques were shown for the measurements of peak velocities and flow rates.Keywords
Funding Information
- Siemens Medical Solutions USA (C00233808)
This publication has 27 references indexed in Scilit:
- Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRIMagnetic Resonance in Medicine, 2013
- Free‐breathing phase contrast MRI with near 100% respiratory navigator efficiency using k‐space‐dependent respiratory gatingMagnetic Resonance in Medicine, 2013
- Intracranial 4D Flow MRI: Toward Individualized Assessment of Arteriovenous Malformation Hemodynamics and Treatment-Induced ChangesAmerican Journal of Neuroradiology, 2013
- Shared velocity encoding: A method to improve the temporal resolution of phase‐contrast velocity measurementsMagnetic Resonance in Medicine, 2011
- Accelerated phase‐contrast cine MRI using k‐t SPARSE‐SENSEMagnetic Resonance in Medicine, 2011
- Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parametersMagnetic Resonance in Medicine, 2008
- Real‐time blood flow imaging using autocalibrated spiral sensitivity encodingMagnetic Resonance in Medicine, 2005
- Applications of phase-contrast flow and velocity imaging in cardiovascular MRIEuropean Radiology, 2005
- Centering the projection reconstruction trajectory: Reducing gradient delay errorsMagnetic Resonance in Medicine, 2003
- Plow quantitation with echo‐planar phase‐contrast velocity mapping: In vitro and in vivo evaluationJournal of Magnetic Resonance Imaging, 1995