A comparative study on evaluation of role of 1.5 mm microplates and 2.0 mm standard miniplates in management of mandibular fractures using bite force as indicator of recommendation
Authors:
- SyedSayeed AhmedSASyedSayeed Ahmed
- MdKalim AnsariMAMdKalim Ansari
Open Access
- 1 January 2016
- journal article
- research article
- Published by Medknow in National Journal of Maxillofacial Surgery
- Vol. 7 (1) , 39-44
Abstract
Aims and Objectives: To compare the maximum voluntary bite force generated at different periods during mandibular fracture healing using miniplates and microplates as means of rigid internal fixation. Materials and Methods: Maximum voluntary bite force was recorded in healthy young individuals of different age group from either gender. Patients suffering from symphyseal and parasymphyseal and body fractures were selected and randomly treated using miniplate and microplate osteosynthesis by open reduction and rigid internal fixation. Postoperative bite forces at intervals of 1st, 2nd, 4th, and 6th week were recorded and compared with control group. Observations and Results: It was noticed that bite forces were significantly reduced in the study groups in comparison to control group and at different intervals of treatment. There was a progressive improvement in the bite force with passage of time. There was no statistical significance in the observed bite force in both the study groups at different intervals of assessment. Conclusion: 1.5 mm microplates provide adequate stability comparable to miniplates for the treatment of fractured mandible and should be preferred over miniplates. We further suggest that bite forces should be considered for the assessment of clinical union of bone as well as studies pertaining to selection of hardware for rigid internal fixation.Keywords
This publication has 16 references indexed in Scilit:
- Bite Force Measurement in Mandibular Parasymphyseal Fractures: A Preliminary Clinical StudyCraniomaxillofacial Trauma & Reconstruction, 2011
- Effect of gender, facial dimensions, body mass index and type of functional occlusion on bite forceJournal of Applied Oral Science, 2011
- Complications of internal fixation of maxillofacial fractures with microplatesJournal of Oral and Maxillofacial Surgery, 1999
- Role of Mini- and Microplate Fixation in Fractures of the Midface and MandibleAnnals of Plastic Surgery, 1995
- Bite forces in patients treated for mandibular angle fractures: Implications for fixation recommendationsJournal of Oral and Maxillofacial Surgery, 1994
- Should titanium miniplates be removed after bone healing is complete?International Journal of Oral and Maxillofacial Surgery, 1993
- Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatmentInternational Journal of Oral and Maxillofacial Surgery, 1993
- A preliminary study of maximum voluntary bite force and jaw muscle efficiency in pre-orthognathic surgery patientsJournal of Oral and Maxillofacial Surgery, 1992
- Mandibular osteosynthesis by miniature screwed plates via a buccal approachJournal of Maxillofacial Surgery, 1978
- Osteosynthesis with miniaturized screwed plates in maxillo-facial surgeryJournal of Maxillofacial Surgery, 1973