Amphotericin B Enzyme-Linked Immunoassay for Clinical Use: Comparison with Bioassay and HPLC
Authors:
- Stanley W ChapmanSCStanley W Chapman
- Thomas C HardinTHThomas C Hardin
- Michael G RinaldiMRMichael G Rinaldi
- J Lee SpencerJSJ Lee Spencer
- Jie DengJDJie Deng
- Gennethel J PennickGPGennethel J Pennick
- Craig J LobbCLCraig J Lobb
- 1 January 1997
- journal article
- research article
- Published by SAGE Publications in Annals of Pharmacotherapy
- Vol. 31 (1) , 39-44
Abstract
OBJECTIVE: To evaluate a new enzyme-linked immunosorbent assay (ELISA) for amphotericin B in serum samples. Results are compared with those obtained by HPLC and bioassay. DESIGN: Comparison of results obtained by ELISA, HPLC, and bioassay. METHODS: We developed a new ELISA using a polyclonal rabbit antibody to measure serum amphotericin B concentrations. Blinded samples of amphotericin B in concentrations of 0.15–78 μg/mL were prepared in human serum and assayed simultaneously by the ELISA, HPLC, and bioassay. The results of each assay were derived from standard curves and evaluated by using the Table Curve 2D computer program. These data were compared by using correlation analysis with evaluation of Pearson's correlation coefficient by Student's t-est. RESULTS: ELISA and bioassay compared favorably at amphotericin B concentrations of 0.3–20 μg/mL with a correlation coefficient of r = 0.993, while ELISA and HPLC compared with a correlation coefficient of r = 0.944. The average coefficient of variation over the range 0.3–20.0 μg/mL was 28% ± 7% for HPLC, 26% ± 9% for ELISA, and 13% ± 4% for bioassay. Comparison of all three assays revealed the highest correlation with the ELISA assay (r = 0.998) for the range of concentrations (0.3–20 μg/mL) routinely achieved. Samples containing concentrations in excess of 20 μg/mL could be diluted. Desiccation for concentrations less than 0.3 μg/mL was not tested. CONCLUSIONS: The determination of serum amphotericin B concentrations by ELISA gave results similar to those obtained by a bioassay and HPLC technique. Although variability appears greater with ELISA, the ease of performing this assay expedites the evaluation of many samples. Finally, this assay may allow the determination of amphotericin B concentrations from lipid formulations without interference from coadministered antibacterials or azole antifungals.Keywords
This publication has 14 references indexed in Scilit:
- Antibodies to nystatin demonstrate polyene sterol specificity and allow immunolabeling of sterols in Saccharomyces cerevisiaeAntimicrobial Agents and Chemotherapy, 1989
- Sensitive high-pressure liquid chromatographic assay for amphotericin B which incorporates an internal standardAntimicrobial Agents and Chemotherapy, 1986
- Induction of amphotericin B-specific antibodies for use in immunoassaysAntimicrobial Agents and Chemotherapy, 1984
- Quantitative extraction of amphotericin B from serum and its determination by high-pressure liquid chromatographyAntimicrobial Agents and Chemotherapy, 1984
- Measurement of amphotericin b in serum or plasma by high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1983
- Quantitation of Amphotericin B with Use of High-Pressure Liquid ChromatographyThe Journal of Infectious Diseases, 1977
- Microassay for Amphotericin BAntimicrobial Agents and Chemotherapy, 1977
- Assay of Flucytosine and Furosemide by High-Pressure Liquid ChromatographyJournal of Pharmaceutical Sciences, 1975
- Analysis of cefoxitin, cephalothin and their deacylated metabolites in human urine by high-performance liquid chromatographyJournal of Chromatography A, 1974
- Ocular Penetration of Amphotericin BArchives of Ophthalmology (1950), 1965