Multicoil shimming of the mouse brain
Open Access
- 25 March 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 66 (3) , 893-900
Abstract
MR imaging and spectroscopy allow the noninvasive measurement of brain function and physiology, but excellent magnetic field homogeneity is required for meaningful results. The homogenization of the magnetic field distribution in the mouse brain (i.e., shimming) is a difficult task due to complex susceptibility‐induced field distortions combined with the small size of the object. To date, the achievement of satisfactory whole brain shimming in the mouse remains a major challenge. The magnetic fields generated by a set of 48 circular coils (diameter 13 mm) that were arranged in a cylinder‐shaped pattern of 32 mm diameter and driven with individual dynamic current ranges of ±1 A are shown to be capable of substantially reducing the field distortions encountered in the mouse brain at 9.4 Tesla. Static multicoil shim fields allowed the reduction of the standard deviation of Larmor frequencies by 31% compared to second order spherical harmonics shimming and a 66% narrowing was achieved with the slice‐specific application of the multicoil shimming with a dynamic approach. For gradient echo imaging, multicoil shimming minimized shim‐related signal voids in the brain periphery and allowed overall signal gains of up to 51% compared to spherical harmonics shimming. Magn Reson Med, 2011.Keywords
This publication has 26 references indexed in Scilit:
- Dynamic shimming of the human brain at 7 TConcepts in Magnetic Resonance Part B, 2010
- Magnetic field homogenization of the human prefrontal cortex with a set of localized electrical coilsMagnetic Resonance in Medicine, 2009
- Sample-specific diamagnetic and paramagnetic passive shimmingJournal of Magnetic Resonance, 2006
- High-order MR shimming: a simulation study of the effectiveness of competing methods, using an established susceptibility model of the human headApplied Magnetic Resonance, 2005
- Mitigation of susceptibility‐induced signal loss in neuroimaging using localized shim coilsMagnetic Resonance in Medicine, 2005
- An evaluation of the use of passive shimming to improve frontal sensitivity in fMRINeuroImage, 2005
- Dynamic shim updating (DSU) for multislice signal acquisitionMagnetic Resonance in Medicine, 2003
- Optimization of static field homogeneity in human brain using diamagnetic passive shimsMagnetic Resonance in Medicine, 2002
- Dynamic shim updating: A new approach towards optimized whole brain shimmingMagnetic Resonance in Medicine, 1996
- Magnet field profiling: Analysis and correcting coil designMagnetic Resonance in Medicine, 1984