MRI‐visible liquid crystal thermometer
- 28 February 2020
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (3) , 1552-1563
Abstract
Purpose: MRI parameters, such as T1, T2, and ADC, of tissue‐mimicking materials in MRI phantoms can exhibit temperature dependence, and bore temperatures can vary over a 10°C range across different MRI systems. If this variation is not accurately corrected for, the quantitative nature of reference or phantom measurements is irrelevant. Available thermometers require opening the phantoms to probe the temperature, which can introduce contaminants that may affect the stability and accuracy of the phantom. An integrated, MRI‐visible thermometer that can be read using typical imaging protocols is needed.Theory and Methods: An MRI‐compatible thermometer was designed using liquid crystals (LCs) that exhibit rapid transitions between the LC cholesteric state and isotropic state in the room temperature range spanning 17°C to 23°C in 1.0°C increments. The LC thermometer was assessed visually and using superconducting quantum interference device magnetometry, NMR, and MRI techniques.Results: The signal generated from the LC thermometer was visible with spin‐echo and gradient‐echo MRI images. The LC state transition temperatures were visually referenced to a National Institute of Standards and Technology‐traceable thermometer, and these LC state transitions were confirmed using superconducting quantum interference device magnetometry and NMR.Conclusions: The LC MR‐visible thermometer had measurable changes in relative signal with temperature, which were invariant to a variety of imaging sequences used.Keywords
Funding Information
- National Institute of Standards and Technology Small Business Innovation Research (70NANB14H297)
This publication has 16 references indexed in Scilit:
- Nuclear magnetic resonance study of the smectic-cholesteric phase transition in a dimesogenic liquid crystalCurrent Applied Physics, 2014
- Practical considerations in T1 mapping of prostate for dynamic contrast enhancement pharmacokinetic analysesMagnetic Resonance Imaging, 2012
- Relationship between Apparent Diffusion Coefficients at 3.0-T MR Imaging and Gleason Grade in Peripheral Zone Prostate CancerRadiology, 2011
- Magnetic-Field Induced Isotropic to Nematic Liquid Crystal Phase TransitionPhysical Review Letters, 2008
- MRI Thermometry Based on PARACEST AgentsJournal of the American Chemical Society, 2005
- Noninvasive thermometry using hyperfine-shifted MR signals from paramagnetic lanthanide complexesInternational Journal of Hyperthermia, 2005
- Real‐time MR temperature mapping of rabbit liver in vivo during thermal ablationMagnetic Resonance in Medicine, 2003
- Determination of paramagnetic lanthanide(III) concentrations from bulk magnetic susceptibility shifts in NMR spectraMagnetic Resonance in Chemistry, 2001
- Bulk magnetic susceptibility shifts in nmr studies of compartmentalized samples: use of paramagnetic reagentsMagnetic Resonance in Medicine, 1990
- Proton Resonance Shift of Water in the Gas and Liquid StatesThe Journal of Chemical Physics, 1966