Reviving XEN63 Gel Stent Patency in Uveitic Glaucoma: A Novel Approach Using 10-0 Nylon Probe
Open Access
- 10 July 2024
- journal article
- case report
- Published by Jaypee Brothers Medical Publishing in Journal of Current Glaucoma Practice
- Vol. 18 (2) , 74-78
Abstract
This case report describes the possibility of XEN63 lumen obstruction at the middle of the device and emphasizes the potential to restore its flow using an ab-externo revision technique involving a 10-0 nylon suture probe, before considering more aggressive surgical interventions. A 55-year-old female with uveitic glaucoma underwent XEN63 implantation but experienced elevated intraocular pressure (IOP) (35 mm Hg) 1 month after the operation, despite medical therapy. A flat bleb, lack of response to medication, yttrium aluminum garnet (YAG) laser treatment, and slit-lamp needling necessitated revision. An ab-externo surgical procedure was performed using a 10-0 nylon probe to release the obstruction, followed by the application of mitomycin C and removal of fibrous tissue and subconjunctival Tenon's capsule. Intraoperatively, flow was observed only after probing with the 10-0 nylon. Postoperatively, the patient's IOP decreased immediately and remained well-controlled at 2 months (8 mm Hg) without requiring further medication. For patients experiencing increased inflammatory response, the XEN63 gel stent may develop deep lumen occlusion that is unresponsive to conventional treatments. This case report introduces a novel surgical technique applicable to various glaucoma devices, utilizing an ab-externo approach with a 10-0 nylon probe. The demonstrated success in reducing IOP suggests its potential as a less invasive alternative to consider before resorting to more aggressive surgical interventions. Marchese V, Randazzo V, Badalamenti R, et al. Reviving XEN63 Gel Stent Patency in Uveitic Glaucoma: A Novel Approach Using 10-0 Nylon Probe. J Curr Glaucoma Pract 2024;18(2):74-78.Keywords
This publication has 19 references indexed in Scilit:
- Morphologie des Sickerkissens mittels optischer KohärenztomographieDie Ophthalmologie, 2022
- XEN Implant Fracture During Needling ProcedureJournal of Glaucoma, 2019
- Possible Intraluminal Obstruction of the XEN45 Gel Stent Observed With Anterior Segment Optical Coherence TomographyJournal of Glaucoma, 2019
- XEN Gel Stent Internal Ostium Occlusion: Ab-Interno RevisionJournal of Glaucoma, 2017
- Mechanism and management of angle closure in uveitisCurrent Opinion in Ophthalmology, 2015
- Uveitis and glaucoma2015
- XEN Gel Stent: The Solution Designed by AqueSys®2013
- The Effect of an Ahmed Glaucoma Valve Implant on Corneal Endothelial Cell Density in Children With Glaucoma Secondary to UveitisAmerican Journal of Ophthalmology, 2013
- Uveitic glaucomaOphthalmology Clinics of North America, 2002
- Ocular Hypotony After Trabeculectomy With Mitomycin CAmerican Journal of Ophthalmology, 1993