Intraoperative Complications With Vitreous Biopsy for Molecular Proteomics
Authors:
- Kapil MishraKMKapil Mishra
- Gabriel VelezGVGabriel Velez
- Teja ChemudupatiTCTeja Chemudupati
- Peter H. TangPTPeter H. Tang
- Prithvi MruthyunjayaPMPrithvi Mruthyunjaya
- Steven R. SanisloSSSteven R. Sanislo
- Vinit B. MahajanVMVinit B. Mahajan
Open Access
- 1 January 2023
- journal article
- research article
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 54 (1) , 32-36
Abstract
Objective: To study the incidence of intraoperative complications while collecting a vitreous sample for proteomic biomarker analyses during small-gauge pars plana vitrectomy (PPV). Methods: A retrospective case series was assembled from the surgical logs and charts of patients who underwent 23-, 25-, and 27-gauge PPV along with an undiluted vitreous biopsy. Primary surgical indication and detailed operative reports were reviewed. Complications specific to vitreous biopsy were assessed while complications related to vitrectomy in general without biopsy were not tabulated. Results: In 1190 eyes that underwent vitreous biopsy, the most common indications for PPV were rhegmatogenous retinal detachment (24.2%), epiretinal membrane (ERM) (21.7%), vitreous hemorrhage (11.0%), uveitis (8.3%), and macular hole (7.5%). An adequate sample of 0.5 cc to 1.0 cc was obtained in all cases. There was one sclerotomy break associated with biopsy, but no instances of lens touch, retinal contusion, retinal detachment, or intraocular hemorrhage. Conclusions: Undiluted vitreous biopsy obtained at the time of small-gauge vitrectomy is a generally safe procedure and may be considered for collection of samples for proteomic analysis. [ Ophthalmic Surg Lasers Imaging Retina 2023;54:32–36.]Keywords
This publication has 19 references indexed in Scilit:
- A biorepository for ophthalmic surgical specimensProteomics – Clinical Applications, 2013
- INTRAOPERATIVE SCLEROTOMY-RELATED RETINAL BREAKS DURING 23-GAUGE PARS PLANA VITRECTOMYRetina, 2013
- Comparison of postoperative intraocular pressure changes between 23-gauge transconjunctival sutureless vitrectomy and conventional 20-gauge vitrectomyEye, 2012
- INTRAOPERATIVE CHOROIDAL DETACHMENT DURING 23-GAUGE VITRECTOMYRetina, 2011
- The Vitreous Trap: A Simple, Surgeon-Controlled Technique for Obtaining Undiluted Vitreous and Subretinal Specimens During Pars Plana VitrectomyRetina, 2010
- Adverse Events After Pars Plana Vitrectomy Among Medicare BeneficiariesArchives of Ophthalmology (1950), 2009
- Diagnostic vitreous biopsy in patients with uveitis: a useful investigation?Clinical & Experimental Ophthalmology, 2005
- Performing Vitreous Biopsy by Perfluorocarbon-Perfused VitrectomyAmerican Journal of Ophthalmology, 2005
- Intraocular-central nervous system lymphomaOphthalmology, 1999
- MICROBIOLOGIC YIELDS AND COMPLICATION RATES OF VITREOUS NEEDLE ASPIRATION VERSUS MECHANIZED VITREOUS BIOPSY IN THE ENDOPHTHALMITIS VITRECTOMY STUDYRetina, 1999