Evaluation and Application of a Paper-Based Device for the Determination of Reactive Phosphate in Soil Solution
- 1 May 2014
- journal article
- research article
- Published by Wiley in Journal of Environmental Quality
- Vol. 43 (3) , 1081-1085
Abstract
The evaluation and validation of a new low-cost microfluidic paper-based analytical device (μPAD) for the determination of reactive phosphate in soil solution is described. This device allows up to 15 replicate measurements of reactive phosphate on one credit card-sized device and requires only a desktop or hand scanner for signal detection and quantification. The proposed method showed a linear response between 0.1 and 1.0 mg L and between 1.0 and 10.0 mg L P with a limit of detection of 0.05 mg L P. When applied to the analysis of soil solution, there was excellent agreement between results obtained using the μPAD and those obtained by a reference spectrophotometric method, as indicated by the following regression equation: [P] = (0.997 ± 0.005)[P] - (0.020 ± 0.008) ( = 0.997; = 110). It was found that the ambient temperature storage stability of the μPAD could be extended to 15 d by incorporating a removable polymeric interleaving sheet between the adjacent paper layers of the device. The observed sensitivity of the μPADs to sunlight, which was manifested by photoreduction of the chromogenic molybdate reagent used in the assay, was overcome by preparing the μPADs with an ultraviolet-filtering laminating material. The proposed method is rapid, with a reaction time of only 10 min, is easy to perform, and is suitable for application in the field.Keywords
Funding Information
- Victorian Department of Environment and Primary Industries
- Australian Research Council (DP1094179)
This publication has 19 references indexed in Scilit:
- The use of a polymer inclusion membrane in a paper-based sensor for the selective determination of Cu(II)Analytica Chimica Acta, 2013
- Determination of aerosol oxidative activity using silver nanoparticle aggregation on paper-based analytical devicesThe Analyst, 2013
- A paper-based device for measurement of reactive phosphate in waterTalanta, 2012
- Development of a Paper-Based Analytical Device for Colorimetric Detection of Select Foodborne PathogensAnalytical Chemistry, 2012
- Paper-based microfluidic devices for analysis of clinically relevant analytes present in urine and salivaAnalytical and Bioanalytical Chemistry, 2010
- Global analysis of nitrogen and phosphorus limitation of primary producers in freshwater, marine and terrestrial ecosystemsEcology Letters, 2007
- Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable BioassaysAngewandte Chemie International Edition, 2007
- Example of use of a desktop scanner for data acquisition in a colorimetric assayClinica Chimica Acta, 2003
- Polyoxometalates as photoelectrochemical models for quantum-sized colloidal semiconducting oxidesSolid State Ionics, 1997
- An automated procedure for the determination of phosphorusWater Research, 1979