Wet or Dry in Dialysis—Can New Technologies Help?
- 1 January 2009
- journal article
- review article
- Published by Wiley in Seminars in Dialysis
- Vol. 22 (1) , 9-12
Abstract
Whereas clinical assessment remains the mainstay of estimating dry weight in dialysis patients, subtle over‐ and under‐hydration may remain undetected, which may result in increased short‐ and long‐term morbidity. Various technological tools have been developed to aid the clinician in the assessment of fluid state in dialysis patients. Chest X‐ray is useful in clinical management, but does not fulfill the need for rapid, noninvasive bedside testing. Vena cava echography provides a reliable estimation of right atrial pressure and was shown to be useful in the clinical management of dialysis patients, but the timing of measurement is of critical importance. New developments in bioimpedance techniques hold great promise for the routine application of this technique in the assessment and follow‐up of hydration state. Cardiac biomarkers have a strong prognostic value, and may reflect overhydration indirectly because of its effect on left ventricular stress. Blood volume monitoring as a tool to assess dry weight needs further validation and standardization. Summarizing technological tools may certainly aid the clinician in the assessment of fluid state, but should always be interpreted in the clinical context of the patient. Controlled studies are needed to definitively establish the role of technological tools in detecting dry weight.Keywords
This publication has 26 references indexed in Scilit:
- The long forgotten salt factorKidney International, 2008
- On the Importance of Pedal Edema in Hemodialysis PatientsClinical Journal of the American Society of Nephrology, 2008
- Current state of bioimpedance technologies in dialysisNephrology Dialysis Transplantation, 2007
- Cardiac biomarkers and survival in haemodialysis patientsEuropean Journal of Clinical Investigation, 2007
- Measuring risk in end-stage renal disease: Is N-terminal pro brain natriuretic peptide a useful marker?Kidney International, 2007
- Diagnostic value of N-terminal pro-B-type natriuretic peptide (NT-proBNP) for left ventricular dysfunction in patients with chronic kidney disease stage 5 on haemodialysisNephrology Dialysis Transplantation, 2007
- Body fluid volume determination via body composition spectroscopy in health and diseasePhysiological Measurement, 2006
- Body composition analysis with bioelectric impedance in adult Indians with ESRD: Comparison with healthy populationKidney International, 2006
- Changes of the Cardiac Architectures and Functions for Chronic Hemodialysis Patients with Dry Weight Determined by EchocardiographyBlood Purification, 2004
- Clinical assessment of dry weightNephrology Dialysis Transplantation, 1996