Improved automatic optic nerve radius estimation from high resolution MRI
- 24 February 2017
- conference paper
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10133, 101331C
Abstract
The optic nerve (ON) is a vital structure in the human visual system and transports all visual information from the retina to the cortex for higher order processing. Due to the lack of redundancy in the visual pathway, measures of ON damage have been shown to correlate well with visual deficits. These measures are typically taken at an arbitrary anatomically defined point along the nerve and do not characterize changes along the length of the ON. We propose a fully automated, three-dimensionally consistent technique building upon a previous independent slice-wise technique to estimate the radius of the ON and surrounding cerebrospinal fluid (CSF) on high-resolution heavily T2-weighted isotropic MRI. We show that by constraining results to be three-dimensionally consistent this technique produces more anatomically viable results. We compare this technique with the previously published slice-wise technique using a short-term reproducibility data set, 10 subjects, follow-up <1 month, and show that the new method is more reproducible in the center of the ON. The center of the ON contains the most accurate imaging because it lacks confounders such as motion and frontal lobe interference. Long-term reproducibility, 5 subjects, follow-up of approximately 11 months, is also investigated with this new technique and shown to be similar to short-term reproducibility, indicating that the ON does not change substantially within 11 months. The increased accuracy of this new technique provides increased power when searching for anatomical changes in ON size amongst patient populations.Keywords
This publication has 22 references indexed in Scilit:
- MRI Acquisition and Analysis Protocol for In Vivo Intraorbital Optic Nerve Segmentation at 3TInvestigative Ophthalmology & Visual Science, 2013
- A reproducible evaluation of ANTs similarity metric performance in brain image registrationNeuroImage, 2011
- Relationship of optic nerve and brain conventional and non-conventional MRI measures and retinal nerve fiber layer thickness, as assessed by OCT and GDx: A pilot studyJournal of the Neurological Sciences, 2009
- Use of T2-weighted magnetic resonance imaging of the optic nerve sheath to detect raised intracranial pressureCritical Care, 2008
- A serial MRI study following optic nerve mean area in acute optic neuritisBrain, 2004
- Use of magnetic resonance imaging to differentiate optic neuritis and nonarteritic anterior ischemic optic neuropathyOphthalmology, 2002
- Race-, Age-, Gender-, and Refractive Error—Related Differences in the Normal Optic DiscArchives of Ophthalmology (1950), 1994
- The Normal Human Optic NerveOphthalmology, 1989
- The Effect of Age on Normal Human Optic Nerve Fiver Number and DiameterOphthalmology, 1989
- Age-related decline of human optic nerve axon populationsAGE, 1987