Influence of substrate stiffness on the phenotype of heart cells
- 15 December 2009
- journal article
- research article
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 105 (6) , 1148-1160
Abstract
Adult cardiomyocytes (CM) retain little capacity to regenerate, which motivates efforts to engineer heart tissues that can emulate the functional and mechanical properties of native myocardium. Although the effects of matrix stiffness on individual CM have been explored, less attention was devoted to studies at the monolayer and the tissue level. The purpose of this study was to characterize the influence of substrate mechanical stiffness on the heart cell phenotype and functional properties. Neonatal rat heart cells were seeded onto collagen‐coated polyacrylamide (PA) substrates with Young's moduli of 3, 22, 50, and 144 kPa. Collagen‐coated glass coverslips without PA represented surfaces with effectively “infinite” stiffness. The local elastic modulus of native neonatal rat heart tissue was measured to range from 4.0 to 11.4 kPa (mean value of 6.8 kPa) and for native adult rat heart tissue from 11.9 to 46.2 kPa (mean value of 25.6 kPa), motivating our choice of the above PA gel stiffness. Overall, by 120 h of cultivation, the lowest stiffness PA substrates (3 kPa) exhibited the lowest excitation threshold (ET; 3.5 ± 0.3 V/cm), increased troponin I staining (52% positively stained area) but reduced cell density, force of contraction (0.18 ± 0.1 mN/mm2), and cell elongation (aspect ratio = 1.3–1.4). Higher stiffness (144 kPa) PA substrates exhibited reduced troponin I staining (30% positively stained area), increased fibroblast density (70% positively stained area), and poor electrical excitability. Intermediate stiffness PA substrates of stiffness comparable to the native adult rat myocardium (22–50 kPa) were found to be optimal for heart cell morphology and function, with superior elongation (aspect ratio > 4.3), reasonable ET (ranging from 3.95 ± 0.8 to 4.4 ± 0.7 V/cm), high contractile force development (ranging from 0.52 ± 0.2 to 1.60 ± 0.6 mN/mm2), and well‐developed striations, all consistent with a differentiated phenotype. Biotechnol. Bioeng. 2010;105: 1148–1160.Keywords
This publication has 49 references indexed in Scilit:
- Biphasic Electrical Field Stimulation Aids in Tissue Engineering of Multicell-Type Cardiac OrganoidsTissue Engineering Part A, 2011
- Spatiotemporal tracking of cells in tissue-engineered cardiac organoidsJournal of Tissue Engineering and Regenerative Medicine, 2009
- Electrical stimulation systems for cardiac tissue engineeringNature Protocols, 2009
- Embryonic cardiomyocytes beat best on a matrix with heart-like elasticity: scar-like rigidity inhibits beatingJournal of Cell Science, 2008
- Accordion-like honeycombs for tissue engineering of cardiac anisotropyNature Materials, 2008
- Polyelectrolyte Multilayer Films of Controlled Stiffness Modulate Myoblast Cell DifferentiationAdvanced Functional Materials, 2008
- Cardiac tissue engineering using perfusion bioreactor systemsNature Protocols, 2008
- Pre‐treatment of synthetic elastomeric scaffolds by cardiac fibroblasts improves engineered heart tissueJournal of Biomedical Materials Research Part A, 2007
- Interactive effects of surface topography and pulsatile electrical field stimulation on orientation and elongation of fibroblasts and cardiomyocytesBiomaterials, 2007
- Evidence of intercellular coupling between co‐cultured adult rabbit ventricular myocytes and myofibroblastsThe Journal of Physiology, 2007