Molecular radiotherapy: The NUKFIT software for calculating the time‐integrated activity coefficient
Authors:
- S. SchimmelSSS. Schimmel
- H. A. KestlerHKH. A. Kestler
- H. HänscheidHHH. Hänscheid
- M. LusterMLM. Luster
- M. FernándezMFM. Fernández
- J. H. BröerJBJ. H. Bröer
- D. NosskeDND. Nosske
- M. LassmannMLM. Lassmann
- G. GlattingG. Glatting
- 10 September 2013
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 40 (10) , 102504
Abstract
Purpose:: Calculation of the time‐integrated activity coefficient (residence time) is a crucial step in dosimetry for molecular radiotherapy. However, available software is deficient in that it is either not tailored for the use in molecular radiotherapy and/or does not include all required estimation methods. The aim of this work was therefore the development and programming of an algorithm which allows for an objective and reproducible determination of the time‐integrated activity coefficient and its standard error.Methods:: The algorithm includes the selection of a set of fitting functions from predefined sums of exponentials and the choice of an error model for the used data. To estimate the values of the adjustable parameters an objective function, depending on the data, the parameters of the error model, the fitting function and (if required and available) Bayesian information, is minimized. To increase reproducibility and user‐friendliness the starting values are automatically determined using a combination of curve stripping and random search. Visual inspection, the coefficient of determination, the standard error of the fitted parameters, and the correlation matrix are provided to evaluate the quality of the fit. The functions which are most supported by the data are determined using the corrected Akaike information criterion. The time‐integrated activity coefficient is estimated by analytically integrating the fitted functions. Its standard error is determined assuming Gaussian error propagation. The software was implemented using MATLAB.Results:: To validate the proper implementation of the objective function and the fit functions, the results of NUKFIT and SAAM numerical, a commercially available software tool, were compared. The automatic search for starting values was successfully tested for reproducibility. The quality criteria applied in conjunction with the Akaike information criterion allowed the selection of suitable functions. Function fit parameters and their standard error estimated by using SAAM numerical and NUKFIT showed differences of Conclusions:: The software tool with its underlying methodology can be employed to objectively and reproducibly estimate the time integrated activity coefficient and its standard error for most time activity data in molecular radiotherapy.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (01EZ1130)
- Bundesministerium für Forschung, Technologie und Raumfahrt (01EZ1130)
This publication has 18 references indexed in Scilit:
- Differences in predicted and actually absorbed doses in peptide receptor radionuclide therapyMedical Physics, 2012
- Dosimetry in molecular nuclear therapyMethods, 2011
- EANM Dosimetry Committee guidance document: good practice of clinical dosimetry reportingEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- In Vivo Formation of γ-H2AX and 53BP1 DNA Repair Foci in Blood Cells After Radioiodine Therapy of Differentiated Thyroid CancerJournal of Nuclear Medicine, 2010
- Radioimmunotherapy with Anti-CD66 Antibody: Improving the Biodistribution Using a Physiologically Based Pharmacokinetic ModelJournal of Nuclear Medicine, 2010
- Three-Dimensional Imaging-Based Radiobiological DosimetrySeminars in Nuclear Medicine, 2008
- Uncertainties in Internal Dose Calculations for RadiopharmaceuticalsJournal of Nuclear Medicine, 2008
- Whole-Body Dosimetry for Targeted Radionuclide Therapy Using Spectral AnalysisCancer Biotherapy and Radiopharmaceuticals, 2005
- SAAM II: Simulation, analysis, and modeling software for tracer and pharmacokinetic studiesMetabolism, 1998
- A relative weighting method for estimating parameters and variances in multiple data setsComputational Statistics & Data Analysis, 1996