Patient-Reported Quality of Life Outcomes after Moderately Hypofractionated and Normofractionated Proton Therapy for Localized Prostate Cancer
Authors:
- Koichiro NakajimaKNKoichiro Nakajima
- Hiromitsu IwataHIHiromitsu Iwata
- Yukiko HattoriYHYukiko Hattori
- Kento NomuraKNKento Nomura
- Kensuke HayashiKHKensuke Hayashi
- Toshiyuki ToshitoTTToshiyuki Toshito
- Yukihiro UmemotoYUYukihiro Umemoto
- Shingo HashimotoSHShingo Hashimoto
- Hiroyuki OginoHOHiroyuki Ogino
- Yuta ShibamotoYSYuta Shibamoto
Open Access
Abstract
We retrospectively evaluated the three-year patient-reported quality of life (QOL) after moderately hypofractionated proton therapy (MHPT) for localized prostate cancer in comparison with that after normofractionated PT (NFPT) using the Expanded Prostate Cancer Index Composite-50. Patients who received MHPT (60–63 Gy (relative biological effectiveness equivalents; RBE)/20–21 fractions) (n = 343) or NFPT (74–78 Gy (RBE)/37–39 fractions) (n = 296) between 2013 and 2016 were analyzed. The minimum clinically important difference (MCID) threshold was defined as one-half of a standard deviation of the baseline value. The median follow-up was 56 months and 83% completed questionnaires at 36 months. Clinically meaningful score deterioration was observed in the urinary domain at 1 month in both groups and in the sexual domain at 6–36 months in the NFPT group, but not observed in the bowel domain. At 36 months, the mean score change for urinary summary was −0.3 (MHPT) and −1.6 points (NFPT), and that for bowel summary was +0.1 and −2.0 points; the proportion of patients with MCID was 21% and 24% for urinary summary and 18% and 29% for bowel summary. Overall, MHPT had small negative impacts on QOL over three years, and the QOL after MHPT and NFPT was similar.Keywords
Funding Information
- Japan Society for the Promotion of Science (20K16830)
This publication has 32 references indexed in Scilit:
- Quality of Life and Toxicity From Passively Scattered and Spot-Scanning Proton Beam Therapy for Localized Prostate CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Patient‐reported outcomes after 3‐dimensional conformal, intensity‐modulated, or proton beam radiotherapy for localized prostate cancerCancer, 2013
- Investigation of the freely available easy-to-use software ‘EZR’ for medical statisticsBone Marrow Transplantation, 2012
- A Beam-Specific Planning Target Volume (PTV) Design for Proton Therapy to Account for Setup and Range UncertaintiesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Patient-Specific Quality Assurance for Prostate Cancer Patients Receiving Spot Scanning Proton Therapy Using Single-Field Uniform DoseInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Modeling of α/β for late rectal toxicity from a randomized phase II study: conventional versus hypofractionated scheme for localized prostate cancerJournal of Experimental & Clinical Cancer Research, 2009
- Radiotherapy Treatment of Early-Stage Prostate Cancer with IMRT and Protons: A Treatment Planning ComparisonInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Fractionation and late rectal toxicityInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Interpretation of Changes in Health-related Quality of LifeMedical Care, 2003
- Is α/β for prostate tumors really low?International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001