Drilling in Ear Surgery: A Comparison of Pre- and Postoperative Bone-conduction Thresholds in both the Conventional and Extended High-frequency Ranges
Authors:
- 1 January 1996
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Audiology
- Vol. 25 (1) , 35-38
Abstract
The pre- and postoperative bone-conduction thresholds for the frequencies 0.25 through 16kHz were compared in 46 ears in which a high-speed ear drill was used. In 15 of these, thresholds were also obtained in the contralateral ear. There was no statistically significant postoperative threshold change at any single frequency in either the operated or the contralateral ear. The mean threshold elevation of 1.4dB for the ipsilateral extended high-frequency octave of 8–16 kHz was marginally significant (p = 0.02), while this was not the case in the contralateral, unoperated ear. These findings are considered to be due to difficulties in placement of the cumbersome Präcitronic KH70 vibrator following bone removal ipsilaterally, with resultant defective transmission to the skull.Keywords
This publication has 20 references indexed in Scilit:
- High-Frequency AudiometryMasking of Air- and Bone-conduction SignalsScandinavian Audiology, 1992
- Measurement of drill-generated noise levels during ear surgeryThe Journal of Laryngology & Otology, 1991
- High‐Frequency Electrostimulation Hearing after MastoidectomyOtolaryngology–Head and Neck Surgery, 1989
- Air Conduction Thresholds after Myringoplasty and Stapes Surgery: A Conventional and High Frequency Audiometric ComparisonAnnals of Otology, Rhinology & Laryngology, 1986
- A system for evaluating auditory function from 8000–20 000 HzThe Journal of the Acoustical Society of America, 1979
- Peroperative Drill-Generated Noise Levels in Ear SurgeryActa Oto-Laryngologica, 1979
- Peroperative Temporary Threshold Shift in Ear Surgery An Electrocochleographic StudyActa Oto-Laryngologica, 1977
- Acoustic trauma from the bone cutting burrThe Journal of Laryngology & Otology, 1976
- Drill-Generated Noise Levels in ear SurgeryActa Oto-Laryngologica, 1976
- High-Tone Sensorineural Losses Following Chronic Ear SurgeryJAMA Otolaryngology–Head & Neck Surgery, 1973