Assessment of the impact of the electromagnetic field of the catenary system on crack formation in reinforced concrete supports
Authors:
- V N LiVLV N Li
- L S DeminaLDL S Demina
- S A VlasenkoSVS A Vlasenko
- E Y TryapkinETE Y Tryapkin
Open Access
- 1 September 2020
- conference paper
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 918 (1)
Abstract
Destruction of reinforced concrete supports is a complex physical and chemical temporary process. The inevitability of destruction is due to the nature of the materials used and the activity of the environment. Centrifuged concrete is an extremely heterogeneous material over the thickness of the products made thereof: in centrifuged structures, several layers are formed over the wall thickness, which differ in their texture and structure. While in operation, the supports are subjected to a complex temperature impact, microorganisms and chemically active media have an impact on them. In addition to the main adverse factors, it is worth noting the effect of the electromagnetic field of the catenary suspension, the impact of which promotes the formation of transverse cracks mainly in the upper part of the support. Therefore, this phenomenon requires the study and development of reinforced concrete support diagnostics and monitoring facilities to provide continuous movement of railway transport and prevent support breakage and falling.Keywords
This publication has 15 references indexed in Scilit:
- The behaviour of Prestressed Concrete Sleeper (pcs) sitting on railway trackIOP Conference Series: Materials Science and Engineering, 2019
- Correlation of Surface Cracks of Concrete due to Corrosion and Bond Strength (between Steel Bar and Concrete)Advances in Civil Engineering, 2019
- Combined Way of Diagnostics of Reinforced Concrete Conical StructuresMaterials Science Forum, 2018
- Evaluating the Quality of Reinforced Concrete Electric Railway Poles by Thermal Nondestructive TestingApplied Sciences, 2018
- Interfacial debonding detection in fiber-reinforced polymer rebar–reinforced concrete using electro-mechanical impedance techniqueStructural Health Monitoring, 2017
- Replacement Criteria for Concrete Catenary PolesQuarterly Report of RTRI, 2017
- Detection and Inspection of Steel Bars in Reinforced Concrete Structures Using Active Infrared Thermography with Microwave Excitation and Eddy Current SensorsSensors, 2016
- Study on Thermal Conductivity of Reinforced Concrete PlateApplied Mechanics and Materials, 2013
- Brillouin Corrosion Expansion Sensors for Steel Reinforced Concrete Structures Using a Fiber Optic Coil Winding MethodSensors, 2011
- Corrosion detection in reinforced concrete using induction heating and infrared thermographyJournal of Civil Structural Health Monitoring, 2011