Instrument for in situ synchronous measurement of the multi-angle volume scattering function and attenuation coefficient
Authors:
- 20 December 2022
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (1) , 248-264
Abstract
An instrument named as Volume Scattering and Attenuation Meter (VSAM) is presented. The VSAM can simultaneously measure the attenuation coefficient and the volume scattering function (VSF) from 10° to 170° with an interval of 10° at 659 nm. Using ultrapure water and NCRM-traceable polystyrene microsphere beads, the VSAM was calibrated, and the conversion factor χ bθ for estimating the backscattering coefficient from the backward VSF was obtained based on Mie theory in the laboratory. For χ bθ , the average relative deviation was no more than 7.77% in the range of 100°-160° between the modeled result based on VSAM and the theoretical result by Boss. Subsequently, the VSAM and ECO-VSF3 were deployed in situ in Zhanjiang Bay. The backscattering coefficient and VSF at the same angles measured by the two instruments were quite consistent. Some remarkable changes in the shape and magnitude of the VSF profile at different stations were found, with land-based pollutants composing an important suspicious source of these changes.Keywords
Funding Information
- National Natural Science Foundation of China (41976170, 41976172, 41976181)
- Scientific and Technological Planning Project of Guangzhou City (201707020023)
- State Key Laboratory of Tropical Oceanography, South China Sea Institute of Oceanology, Chinese Academy of Sciences (LTOZZ2003)
This publication has 26 references indexed in Scilit:
- An Instrument for In Situ Measuring the Volume Scattering Function of Water: Design, Calibration and Primary ExperimentsSensors, 2012
- Effect of inherent optical properties variability on the chlorophyll retrieval from ocean color remote sensing: an in situ approachOptics Express, 2010
- A New Method for the Measurement of the Optical Volume Scattering Function in the Upper OceanJournal of Atmospheric and Oceanic Technology, 2003
- Absorption spectrum (380–700 nm) of pure water II Integrating cavity measurementsApplied Optics, 1997
- Significant relationship between the backward scattering coefficient of sea water and the scatterance at 120°Applied Optics, 1990
- A spectral light absorption meter for measurements in the seaLimnology and Oceanography, 1975
- OBSERVATIONS OF LIGHT SCATTERING IN SEAWATER1Limnology and Oceanography, 1968
- Nephelometer for the Measurement of Volume Scattering Function in Situ*†Journal of the Optical Society of America, 1958
- Photoelectric Light-Scattering Photometer for Determining High Molecular Weights*Journal of the Optical Society of America, 1950
- Angular Distribution of Light Scattered in LiquidsJournal of the Optical Society of America, 1941