Validation of the non-stereo corresponding points stereoradiographic 3D reconstruction technique
Authors:
- 1 March 2001
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 39 (2) , 152-158
Abstract
Several 3D reconstruction techniques deriving from stereoradiographic DLT have been presented during the last 15 years, but these techniques have usually been limited in accuracy because of the small number of corresponding anatomical landmarks identified on both radiographs. A new technique has recently been proposed to perform 3D reconstruction of the spine using not only the stereo-corresponding anatomical landmarks (seen on both frontal and sagittal X-ray films) but also some non-stereo-corresponding ones. This technique (called non-stereo-corresponding points or NSCP) has already been used for cervical dry vertebrae. In the present study, we focus on the validation of this technique for lumbar vertebrae by comparing four techniques: direct measurement, CT scan, 3D reconstruction by stereoradiography using a direct linear transformation (DLT) algorithm and the NSCP technique. The accuracy of the NSCP technique was also evaluated on different vertebral regions. The global results show mean errors of 1.1 mm and maximum of 7.8 mm with regard to direct measurements. These mean errors are close to those obtained using 3D reconstructions from CT scan using 1 mm cuts.Keywords
This publication has 19 references indexed in Scilit:
- A note on some identification problems arising in roentgen stereo photogrammetric analysisJournal of Biomechanics, 1994
- Optimized vertical stereo base radiographic setup for the clinical three-dimensional reconstruction of the human spineJournal of Biomechanics, 1994
- An investigation on the accuracy of three-dimensional space reconstruction using the direct linear transformation techniqueJournal of Biomechanics, 1994
- Comparative assessment of two algorithms for calibrating stereophotogrammetric systemsJournal of Biomechanics, 1993
- A contouring program based on dual kriging interpolationEngineering with Computers, 1993
- A Biomechanical Analysis of Short Segment Spinal Fixation Using a Three-Dimensional Geometric and Mechanical ModelSpine, 1993
- An Analytical Investigation of the Mechanics of Spinal InstrumentationSpine, 1988
- High-precision three-dimensional photogrammetric calibration and object space reconstruction using a modified DLT-approachJournal of Biomechanics, 1988
- A finite element study of a lumbar motion segment subjected to pure sagittal plane momentsJournal of Biomechanics, 1986
- Stereo radiography of lumbar spine motionActa Orthopaedica, 1985