Enhanced immunofluorescence detection of a protein marker using a PAA modified ZnO nanorod array-based microfluidic device
- 21 August 2018
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 10 (37) , 17663-17670
Abstract
Zinc oxide (ZnO) often serves as protein microarray substrates owing to its outstanding fluorescence enhancement effect. However, the integration of functional substrates with microfluidic technology to detect cancer biomarkers still needs to be optimized and promoted, for example, the optimization of micro/nanostructure and hydrophilic modification strategies for fluorescence immunoassays. Here, ZnO nanorod arrays were constructed on the inner wall of glass capillaries through a microfluidic chemical method, and the electrostatic layer by layer self-assembly was applied to modify the nanorod array with hydrophilic polyelectrolyte-polyacrylic acid (PAA). The effects of the flow rate and the reagent concentration on the morphology of the ZnO nanorod array were investigated. The ZnO nanorod array-based glass capillary, prepared at 25 μL min−1 for 4 min with 50 mM Zn2+ in solution, showed a remarkable enhancement in fluorescence performance. In addition, the introduction of PAA suppressed the interference of nonspecific protein and improved the antibody loading capacity effectively. In the detection of carcinoembryonic antigen, the limit of detection reached 100 fg mL−1, which indicated that the ZnO@PAA nanorod array-based microfluidic device exhibits remarkable fluorescence detection performance towards protein markers and possesses potential to be applied to point-of-care diagnostics and high throughput cancer biomarker detection.Keywords
Funding Information
- National Natural Science Foundation of China (51503035, 81803090, SYGZRPY2017040)
- Ministry of Education of the People's Republic of China (111-2-04, IRT_16R13)
- Shanghai Jiao Tong University (YG2017QN43)
- Foundation of Shanghai Municipal Commission of Health and Family Planning (20174Y0123)
This publication has 40 references indexed in Scilit:
- Label-Free Colorimetric Aptasensor Based on Nicking Enzyme Assisted Signal Amplification and DNAzyme Amplification for Highly Sensitive Detection of ProteinAnalytical Chemistry, 2013
- Microfluidic Chips for Point‐of‐Care ImmunodiagnosticsAdvanced Materials, 2011
- Poly[oligo(ethylene glycol) methacrylate‐co‐glycidyl methacrylate] Brush Substrate for Sensitive Surface Plasmon Resonance Imaging Protein ArraysAdvanced Functional Materials, 2010
- Randomly Oriented ZnO Nanorods As Advanced Substrate for High-Performance Protein MicroarraysACS Applied Materials & Interfaces, 2010
- Nanostructured Silver-Based Surfaces: New Emergent Methodologies for an Easy Detection of AnalytesACS Applied Materials & Interfaces, 2009
- Continuous-flow microfluidic printing of proteins for array-based applications including surface plasmon resonance imagingAnalytical Biochemistry, 2008
- Separation distance dependent fluorescence enhancement of fluorescein isothiocyanate by silver nanoparticlesChemical Communications, 2006
- Nanoscale ZnO‐Enhanced Fluorescence Detection of Protein InteractionsAdvanced Materials, 2006
- Enhancement of Single-Molecule Fluorescence Using a Gold Nanoparticle as an Optical NanoantennaPhysical Review Letters, 2006
- Proteomic applications for the early detection of cancerNature Reviews Cancer, 2003