Evaluating the effect of denoising submillimeter auditory fMRI data with NORDIC
Authors:
Open Access
- 14 August 2024
- journal article
- Published by MIT Press in Imaging Neuroscience
- Vol. 2, 1-18
Abstract
Functional magnetic resonance imaging (fMRI) has emerged as an essential tool for exploring human brain function. Submillimeter fMRI, in particular, has emerged as a tool to study mesoscopic computations. The inherently low signal-to-noise ratio (SNR) at submillimeter resolutions warrants the use of denoising approaches tailored at reducing thermal noise—the dominant contributing noise component in high-resolution fMRI. NOise Reduction with DIstribution Corrected Principal Component Analysis (NORDIC PCA) is one of such approaches, and has been benchmarked against other approaches in several applications. Here, we investigate the effects that two versions of NORDIC denoising have on auditory submillimeter data. While investigating auditory functional responses poses unique challenges, we anticipated NORDIC to have a positive impact on the data on the basis of previous applications. Our results show that NORDIC denoising improves the detection sensitivity and the reliability of estimates in submillimeter auditory fMRI data. These effects can be explained by the reduction of the noise-induced signal variability. However, we did observe a reduction in the average response amplitude (percent signal change) within regions of interest, which may suggest that a portion of the signal of interest, which could not be distinguished from general i.i.d. noise, was also removed. We conclude that, while evaluating the effects of the signal reduction induced by NORDIC may be necessary for each application, using NORDIC in high-resolution auditory fMRI studies may be advantageous because of the large reduction in variability of the estimated responses.Keywords
All Related Versions
This publication has 70 references indexed in Scilit:
- Slab-selective, BOLD-corrected VASO at 7 Tesla provides measures of cerebral blood volume reactivity with high signal-to-noise ratioMagnetic Resonance in Medicine, 2013
- Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRIMagnetic Resonance in Medicine, 2010
- 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head imagesMagnetic Resonance in Medicine, 2001
- Imaging brain function in humans at 7 TeslaMagnetic Resonance in Medicine, 2001
- Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICORMagnetic Resonance in Medicine, 2000
- Anatomically Informed Basis FunctionsNeuroImage, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Analysis of fMRI data by blind separation into independent spatial componentsHuman Brain Mapping, 1998
- Retrospective estimation and correction of physiological fluctuation in functional MRIMagnetic Resonance in Medicine, 1995
- BOLD Based Functional MRI at 4 Tesla Includes a Capillary Bed Contribution: Echo‐Planar Imaging Correlates with Previous Optical Imaging Using Intrinsic SignalsMagnetic Resonance in Medicine, 1995