What happened when medical staff in Beijing, China wore over-apron dosemeters?
- 29 May 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (11) , 1190-1194
Abstract
The wearing method of personal dosemeters for medical staff changed from under to outside the operator’s protective apron in April 2020. We measured the radiation dose Hp(10) for medical staff in Beijing from September 2020 to October 2021. The study population consisted of 3291 medical staff. All participants were divided into three groups. After excluding unusually low doses, the collected data higher than the detection limit involved 811 (7.8%) of 10 395 readings from 479 (14.6%) of 3291 staff. The mean equivalent dose was 1.4 mSv/3 months, with an SD of 2.3 mSv. The calculated average annual effective doses of radiation workers in the three groups after the interventional procedures from September 2020 to October 2021 ranged from 0.47 to 0.63 mSv/year, with median values of 0.32, 0.23 and 0.26 mSv/year, respectively.Keywords
Funding Information
- Capital’s Funds for Health Improvement and Research (2022-2G-3019)
- Construction Project of High-level Public health Technical Personnel in Beijing
This publication has 11 references indexed in Scilit:
- ICRP Publication 139: Occupational Radiological Protection in Interventional ProceduresAnnals of the ICRP, 2018
- Health Effects from Occupational Radiation Exposure among Fluoroscopy-Guided Interventional Medical Workers: A Systematic ReviewJournal of Vascular and Interventional Radiology, 2018
- Mortality in U.S. Physicians Likely to Perform Fluoroscopy-guided Interventional Procedures Compared with Psychiatrists, 1979 to 2008Radiology, 2017
- Seasonal variations of temperature-related mortality burden from cardiovascular disease and myocardial infarction in ChinaEnvironmental Pollution, 2017
- Head and Neck Radiation Dose and Radiation Safety for Interventional PhysiciansJACC: Cardiovascular Interventions, 2017
- A REVIEW OF TWO METHODS USED IN THE USA TO ASSESSHEDURING FLUOROSCOPIC-BASED RADIOLOGYRadiation Protection Dosimetry, 2016
- Occupational hazards of interventional cardiologyCardiovascular Revascularization Medicine, 2013
- Brain and Neck Tumors Among Physicians Performing Interventional ProceduresThe American Journal of Cardiology, 2013
- Staff Doses in Interventional Radiology: A National SurveyJournal of Vascular and Interventional Radiology, 2012
- CANCER INCIDENCE AND RISK ESTIMATION AMONG MEDICAL X-RAY WORKERS IN CHINA, 1950–1995Health Physics, 2002