Turbine Bypass, Mass Inventory, and Mixed-Mode Generator Power Control of S-CO2Recompression Cycle

Authors:

Abstract
The supercritical carbon dioxide (S-CO2) recompression cycle is a power conversion cycle compatible with intermediate-temperature nuclear reactors. The main advantage of the S-CO2 cycle is relatively high efficiency (∼47% at the turbine inlet temperature of 650°C). The dynamic characteristics and control of this cycle remain areas of active research because of the cycle’s unique features, in particular, large fluid property changes near the critical point. This paper reports the conceptual development of a dynamic S-CO2 recompression cycle controller designed to efficiently respond to a demand for reduction of generator electric power. The S-CO2 cycle generator electric power production can be controlled using either turbine bypass (TB) or mass inventory (MI) controllers. Turbine bypass is a fast response controller, which reduces generator power by opening the TB valve. Mass inventory is a slow response controller, with a time constant an order of magnitude larger than that of the TB controller. ...