Automated measurement of the cyclic activity of respiratory muscles
Authors:
- M.J. DrinnanMDM.J. Drinnan
- A. MurrayAMA. Murray
- J.E.S. WhiteJWJ.E.S. White
- A.J. SmithsonASA.J. Smithson
- G.J. GibsonGGG.J. Gibson
- C.J. GriffithsCGC.J. Griffiths
- 1 November 1994
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 16 (6) , 477-483
Abstract
A microcomputer-based system developed for the automated analysis of the electromyogram (EMG) recorded from respiratory muscles in a variety of situations is described. In addition, an assessment of the performance of the system is presented, along with data relating intercostal EMG activity to ribcage movement in seated subjects. Studies were performed on sixteen normal subjects--non smokers, mean (+/- SD) age 31 (+/- 6) years, mean (+/- SD) mass 78 (+/- 8) kg--of which fifteen studies proved suitable for analysis. Each study lasted for a period of five minutes, during which time recordings of intercostal EMG, ribcage postero-anterior displacement (RCPA) and airflow were made. For every breath taken by each of the subjects, the peak integrated EMG activity (iEMGpeak) was measured both by hand and by the automated system. The automated and manual measurements of iEMGpeak, which ranged from 0.0 to 91.3 microV, differed by only -0.82 +/- 3.34 microV (mean +/- SD). The index iEMGpeak and two additional indices of iEMG activity (iEMGmean, iEMGarea) were evaluated with respect to RCPA, a measure of overall respiratory activity. The indices of iEMG were observed to show an exponential dependence on RCPAamp, the amplitude of ribcage motion. Following a log transformation to linearise the relationship, the correlation of each index with RCPAamp was evaluated; iEMGpeak and iEMGarea correlated similarly with RCPAamp (no significant difference at 5% level), but iEMGmean was found to be a significantly different (p < 0.001) and poorer correlate. We conclude that the automated analysis of respiratory iEMG as described in this paper can provide results showing consistency with manual measurement.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 10 references indexed in Scilit:
- High-pass filtering to remove electrocardiographic interference from torso EMG recordingsClinical Biomechanics, 1993
- A video system for investigating breathing disorders during sleep.Thorax, 1991
- Mechanical Action of the Interosseous Intercostal Muscles as a Function of Lung VolumeAmerican Review of Respiratory Disease, 1990
- Fluctuation in timing of upper airway and chest wall inspiratory muscle activity in obstructive sleep apneaJournal of Applied Physiology, 1990
- Accessory muscle activity during sleep in chronic obstructive pulmonary diseaseJournal of Applied Physiology, 1984
- Measurement of chest wall movement; design, performance and clinical use of a four-channel magnetometer instrumentClinical Physics and Physiological Measurement, 1983
- Effect of pressure and timing of contraction on human diaphragm fatigueJournal of Applied Physiology, 1982
- Changes in ventilation and chest wall mechanics during sleep in normal adolescentsJournal of Applied Physiology, 1981
- Diaphragmatic muscle toneJournal of Applied Physiology, 1979
- Mechanics of the rib cage and diaphragm during sleepJournal of Applied Physiology, 1977