Quantification of Arteriovenous Shunting in Renal Cell Carcinoma
Authors:
- 1 February 1981
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 125 (2) , 161-163
Abstract
Arteriovenous shunting was quantitated with 20 plus or minus 10 mu 99mtechnetium human albumin microspheres in 12 patients with angiographically hypervascular renal cell carcinomas. Arteriovenous shunting was diagnosed angiographically when the renal vein was opacified during the arterial phase. With use of an angiographic catheter 2 to 3 mCi. 99mtechnetium human albumin microspheres were first injected into the renal artery directly supplying the tumor. Thereafter, 0.5 to 1 mCi. microspheres were injected into the inferior vena cava. Scintillation counts over the right lung were obtained immediately after each injection. The ratio between the 2 counts established the rate of tumor shunting after correction for dose difference and decay. Nine patients without angiographic evidence of arteriovenous shunting had mean shunt rates of 15 per cent, whereas 3 patients with angiographically visible shunting had significantly higher shunt rates of 57 per cent (p less than 0.001). It is concluded that angiography discovers only massive arteriovenous shunting in patients with renal cell carcinoma, whereas a fair degree of arteriovenous shunting may go undetected. The significance of minimal or moderate arteriovenous shunting in patients with renal cell carcinoma needs further investigation. The microsphere quantitation method can be applied routinely to angiography.Keywords
This publication has 9 references indexed in Scilit:
- Urinary excretion of 99mTc administered as microspheres.Radiology, 1980
- Verification and Quantification of Anatomic Arteriovenous Shunting in a HypernephromaJournal of Urology, 1974
- Measurement of cardiac output distribution using microspheres. Some practical and theoretical considerationsCardiovascular Research, 1974
- Absence of Arteriovenous Shunting in Peripheral Arterial DiseaseInvestigative Radiology, 1974
- HYPERNEPHROMAS WITH MASSIVE ARTERIOVENOUS FISTULASAmerican Journal of Roentgenology, 1973
- Perfusion Studies with Technetium-99m Human Albumin Microspheres (HAM)Radiology, 1970
- Studies of the Circulation with Radioactive MicrospheresInvestigative Radiology, 1969
- Arteriography in the Diagnosis of Renal CarcinomaRadiology, 1968
- Radiographic Manifestations of Massive Arteriovenous Fistula in Renal CarcinomaRadiology, 1965