Compound-Specific Chlorine Isotope Analysis: A Comparison of Gas Chromatography/Isotope Ratio Mass Spectrometry and Gas Chromatography/Quadrupole Mass Spectrometry Methods in an Interlaboratory Study
- 21 September 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (20) , 7624-7634
Abstract
Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of 37Cl/35Cl instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of δ37Cl was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1σ ≈ 0.1‰), to GC/qMS (1σ ≈ 0.2–0.5‰ for Agilent GC/qMS and 1σ ≈ 0.2–0.9‰ for Thermo GC/qMS). Nonetheless, δ37Cl values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications.Keywords
This publication has 35 references indexed in Scilit:
- Stable isotope fractionation to investigate natural transformation mechanisms of organic contaminants: principles, prospects and limitationsJournal of Environmental Monitoring, 2010
- C and N Isotope Fractionation Suggests Similar Mechanisms of Microbial Atrazine Transformation Despite Involvement of Different Enzymes (AtzA and TrzN)Environmental Science & Technology, 2009
- Monitoring and evaluation of dechlorination processes using compound‐specific chlorine isotope analysisRapid Communications in Mass Spectrometry, 2007
- Insight into Methyl tert-Butyl Ether (MTBE) Stable Isotope Fractionation from Abiotic Reference ExperimentsEnvironmental Science & Technology, 2007
- Compound-specific chlorine isotope ratios of TCE, PCE and DCE isomers by direct injection using CF-IRMSApplied Geochemistry, 2006
- Mass Spectrometer Hardware for Analyzing Stable Isotope Ratios2004
- Characterisation of chlorinated hydrocarbons from chlorine and carbon isotopic compositions: scope of application to environmental problemsApplied Geochemistry, 2001
- Chlorine Isotope Investigation of Natural Attenuation of Trichloroethene in an Aerobic AquiferEnvironmental Science & Technology, 1998
- Stable chlorine and carbon isotope measurements of selected chlorinated organic solventsApplied Geochemistry, 1995
- Natural chlorine isotope variationsNature, 1984