Loop-Mediated Isothermal Amplification for Rapid and Semiquantitative Detection of Loa loa Infection
Open Access
- 1 June 2014
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 52 (6) , 2071-2077
Abstract
Rapid and accurate tests are currently needed to identify individuals with high levels of Loa loa microfilaria (mf), so that these individuals may be excluded from mass ivermectin administration campaigns against onchocerciasis and lymphatic filariasis being conducted in areas where Onchocerca volvulus , Wuchereria bancrofti , and L. loa are coendemic. To address this need, colorimetric loop-mediated isothermal amplification (LAMP) assays targeting the L. loa -specific gene sequences LLMF72 and LLMF342 were developed for the detection and quantification of L. loa microfilaremia. Both LAMP assays were highly specific (100%) for L. loa infection compared to the absence of infection or infection with related filarial pathogens. The LLMF72-based LAMP assay showed greater analytic sensitivity (limit of detection, 0.1 pg/ml of genomic DNA [gDNA] and/or 5 mf/ml) than the LLMF342-based LAMP assay (10 pg/ml of gDNA and/or 50 mf/ml), and its analytic sensitivity was similar to that of LLMF72-based quantitative PCR (qPCR). A high level of correlation was observed between microfilaria counts as determined by LLMF72-based qPCR and time to positivity by the LAMP assay, and performance measures of sensitivity, specificity, and positive and negative predictive values were similar for both assays when applied to field-collected clinical samples. By simply varying the run time, the LAMP assay was able to accurately distinguish individuals at risk for serious adverse events (SAEs) after exposure to ivermectin, using thresholds of >5,000 mf/ml and >30,000 mf/ml as indicators of increasing levels of risk. In summary, LLMF72 LAMP represents a new molecular diagnostic tool that is readily applicable as a point-of-care method for L. loa microfilarial detection and quantification in resource-limited countries where L. loa infection is endemic.Keywords
This publication has 44 references indexed in Scilit:
- Clinical utility of loop-mediated isothermal amplification for rapid diagnosis of Mycoplasma pneumoniae in childrenJournal of Medical Microbiology, 2014
- Detection of Acute Toxoplasmosis in Pigs Using Loop-Mediated Isothermal Amplification and Quantitative PCRThe Korean Journal of Parasitology, 2013
- Comparison of a loop-mediated isothermal amplification for orf virus withquantitative real-time PCRVirology Journal, 2013
- Loiasis with Peripheral Nerve Involvement and Spleen LesionsThe American Journal of Tropical Medicine and Hygiene, 2011
- Evaluation of a Loop-Mediated Isothermal Amplification Method Using Fecal Specimens for Differential Detection of Taenia Species from HumansJournal of Clinical Microbiology, 2010
- Loa loa Microfilarial Periodicity in Ivermectin-Treated Patients: Comparison Between Those Developing and Those Free of Serious Adverse EventsThe American Journal of Tropical Medicine and Hygiene, 2009
- Encephalopathy after Ivermectin Treatment in a Patient Infected with Loa Loa and Plasmodium spp.The American Journal of Tropical Medicine and Hygiene, 2008
- Accelerated reaction by loop-mediated isothermal amplification using loop primersMolecular and Cellular Probes, 2002
- Loop-mediated isothermal amplification of DNANucleic Acids Research, 2000
- Challenges for the future: loiasisPathogens and Global Health, 1998