Demonstration of CEST MRI in an Animal Model of Acute Ischemic Stroke at 15. 2 T With Simple Linearization for B 1 Inhomogeneity Correction
- 24 March 2026
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 839-851
Abstract
Purpose: CEST at ultra‐high fields such as 15.2 T benefits significantly from increased signal and increased spectral resolution. However, inhomogeneous fields become a confounding issue for B 0 and B 1 . While B 0 inhomogeneity correction is widely studied and implemented, methods for B 1 correction have been limited to interpolation, which requires close to ground truth sampling across B 1 or sophisticated methods that increase data acquisition requirements. This work demonstrates a simple and easy‐to‐employ model‐based linearization that allows for reasonable B 1 correction with as low as two B 1 samples for implementation. Methods: Simulation and in vivo rodent brain CEST data at 15.2 T were tested for reasonable B 1 correction using a surface coil to demonstrate an exaggerated situation of B 1 inhomogeneity. Individual exchange fitting was performed, and quantified maps were examined for apparent residual B 1 dependencies, and quantitative values were examined for consistency across animals. Results: Simulation showed linearization significantly improved linear dependency over simple linear interpolation, even when multiple pools were involved. B 1 corrected Z‐spectra demonstrated reasonable consistency across animals, and parameter maps of simple quantifying CEST parameters demonstrated little B 1 dependency. Fitting CEST curves demonstrates similar consistency and independence from B 1 . Finally, comparison of parameters across animals demonstrates reasonable consistency after B 1 correction. Conclusion: The simple linearization described in this paper offers a facile way to rapidly correct for B 1 inhomogeneity with minimally required additional spectral sampling. This method can have significant advantages, particularly in scan‐time restricted situations where multiple Z‐spectra at more than two power levels are not feasible.Keywords
Funding Information
- Halle Institute for Global Research, Emory University
This publication has 61 references indexed in Scilit:
- Quantitative chemical exchange sensitive MRI using irradiation with toggling inversion preparationMagnetic Resonance in Medicine, 2012
- MR imaging of the amide‐proton transfer effect and the pH‐insensitive nuclear overhauser effect at 9.4 TMagnetic Resonance in Medicine, 2012
- Chemical exchange saturation transfer (CEST): What is in a name and what isn't?Magnetic Resonance in Medicine, 2011
- Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protonsMagnetic Resonance in Medicine, 2010
- Fast multislice pH‐weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiationMagnetic Resonance in Medicine, 2010
- Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experimentsMagnetic Resonance in Medicine, 2009
- Correction for artifacts induced by B0 and B1 field inhomogeneities in pH‐sensitive chemical exchange saturation transfer (CEST) imagingMagnetic Resonance in Medicine, 2007
- Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRIMagnetic Resonance in Medicine, 2005
- 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head imagesMagnetic Resonance in Medicine, 2001
- Correction for geometric distortion in echo planar images from B0 field variationsMagnetic Resonance in Medicine, 1995