High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume
- 7 August 2014
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 24 (12) , 3260-3268
Abstract
To evaluate the image quality, radiation dose and diagnostic accuracy of 80kVp, high-pitch CT pulmonary angiography (CTPA) with iterative reconstruction using 20 ml of contrast agent. One hundred patients with suspected pulmonary embolism (PE) were randomly divided into two groups (n = 50 each; group A, 100 kVp, 1.2 pitch, 60 ml of contrast medium and filtered back projection algorithm; group B, 80 kVp, 2.2 pitch, 20 ml of contrast medium and sinogram affirmed iterative reconstruction). Image quality, diagnostic accuracy and radiation dose were evaluated and compared. Mean CT numbers of pulmonary arteries in group B were higher than those in group A (all P < 0.001). Contrast-to-noise ratio and signal-to-noise ratio of group B were higher than those of group A (both P < 0.001). There was no significant difference in subjective image quality scores between two groups (P = 0.807). The interobserver agreement was excellent (k = 0.836). There was no significant difference in diagnostic accuracy between the two groups (P > 0.05). Compared with group A, radiation dose of group B was reduced by 50.3 % (P < 0.001). High-pitch CTPA at 80 kVp can obtain sufficient image quality in normal-weight individuals with 20 ml of contrast agent and half the radiation dose of a conventional CTPA protocol. • CTPA is feasible at 80 kVp using only 20 ml of contrast agent. • High-pitch CTPA at 80 kVp has an effective dose under 1 mSv. • This CTPA protocol can obtain sufficient image quality in normal-weight individuals.Keywords
This publication has 31 references indexed in Scilit:
- CT pulmonary angiography using a reduced volume of high-concentration iodinated contrast medium and multiphasic injection to achieve dose reductionClinical Radiology, 2014
- High-Pitch ECG-Synchronized Pulmonary CT Angiography Versus Standard CT Pulmonary Angiography: A Prospective Randomized StudyAmerican Journal of Roentgenology, 2013
- Pulmonary CT Angiography as First-Line Imaging for PE: Image Quality and Radiation Dose ConsiderationsAmerican Journal of Roentgenology, 2013
- Initiatives Focus on Limiting Radiation Exposure to Patients During CT ScansJAMA, 2013
- Pulmonary 64-MDCT Angiography With 30 mL of IV Contrast Material: Vascular Enhancement and Image QualityAmerican Journal of Roentgenology, 2012
- Intravenous contrast material administration at high-pitch dual-source CT pulmonary angiography: Test bolus versus bolus-tracking techniqueEuropean Journal of Radiology, 2012
- Low-dose CT of the lung: potential value of iterative reconstructionsEuropean Radiology, 2012
- Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patientsEuropean Radiology, 2009
- CT Angiography of Pulmonary Arteries to Detect Pulmonary Embolism: Improvement of Vascular Enhancement with Low Kilovoltage SettingsRadiology, 2006
- Contrast-media-induced nephrotoxicity: a consensus reportEuropean Radiology, 1999