A phase I trial evaluating the safety, tolerability, pharmacokinetics and pharmacodynamics of intravenously administered low-anticoagulant heparin (M6229) in critically ill sepsis patients
Open Access
- 18 August 2025
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 13 (1) , 1-15
Abstract
Background: Histones released in response to cellular injury are important mediators of organ failure and death in sepsis. Preclinical studies demonstrate that neutralization of histones in sepsis is associated with improved outcome. M6229 is a low-anticoagulant heparin able to neutralize histones. We aimed to evaluate the safety, tolerability, pharmacokinetics and pharmacodynamics of M6229 in critically ill patients with sepsis. Methods: This was a first-in-human, phase I, monocenter trial in patients with sepsis admitted to the intensive care unit (ICU). Patients received a single 6 h intravenous infusion of M6229. A modified continual reassessment method (mCRM) with escalation overdose control was used for dose-escalation. The model was based on the probability of activated partial thromboplastin time (aPTT) being above 90 s (i.e., dose limiting pharmacologic event, DLPE). Three cohorts were studied (1: 0.15 mg/kg/h; 2: 0.45 mg/kg/h; 3: 0.90 mg/kg/h). Results: Ten patients were included. The aPTT increased proportionally with increasing dosages of M6229 and decreased rapidly after infusion cessation. One DLPE occurred (aPTT of 100 s). Based on the mCRM model and data safety monitoring board recommendations, the maximum tolerated dose was defined as 0.9 mg/kg/h for a 6 h infusion of M6229. No serious adverse events were related to study drug infusion. An increase in QTc was probably related to infusion in one patient. M6229 showed close to dose-proportional pharmacokinetics. Total histone H3 and H2b plasma levels increased during and/or in the hours after M6229 infusion in all patients. In four out of five patients with plasma samples positive for histone H3, proteolytic cleavage was observed after infusion start. A decrease in sequential organ failure assessment score was observed in the days after infusion in 70% of patients. Conclusions: M6229 was deemed safe to use in critically ill sepsis patients. Our results suggest intravascular neutralization of histones by M6229. Future clinical studies need to confirm our findings and the efficacy of M6229.Keywords
Funding Information
- Ministry of Economic Affairs/Health Holland (TKI PPP)
This publication has 34 references indexed in Scilit:
- Unfractionated Heparin Enhances Sepsis Prognosis Through Inhibiting Drp1‐Mediated Mitochondrial Quality ImbalanceAdvanced Science, 2024
- A dose‐adjusted, open‐label, pilot study of the safety, tolerability, and pharmacokinetics of STC3141 in critically ill patients with sepsisPharmacology Research & Perspectives, 2024
- Design and characterization of novel activated protein C variants for the proteolysis of cytotoxic extracellular histone H3Journal of Thrombosis and Haemostasis, 2023
- A focus on the roles of histones in health and diseasesClinical Biochemistry, 2021
- Enhancing Recovery From SepsisJAMA, 2018
- Should all septic patients be given systemic anticoagulation? NoIntensive Care Medicine, 2017
- The Third International Consensus Definitions for Sepsis and Septic Shock (Sepsis-3)JAMA, 2016
- Bleeding and risk of death with hydroxyethyl starch in severe sepsis: post hoc analyses of a randomized clinical trialIntensive Care Medicine, 2013
- The accumulation of circulating histones on heparan sulphate in the capillary glycocalyx of the lungsBiomaterials, 2013
- The Berlin definition of ARDS: an expanded rationale, justification, and supplementary materialIntensive Care Medicine, 2012