Water-Covered Roof Versus Inverted Flat Roof on the Mediterranean Coast: A Comparative Study of Thermal and Energy Behavior
Open Access
- 27 March 2020
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 10 (7) , 2288
Abstract
Reservoir, or water-collecting roofs present greater thermal inertia than inverted flat roofs due to the mass of water they contain. This feature gives them better thermal performance and leads to greater stability in the indoor air temperature Ti and the wall surface temperatures. In the summer, they can dampen the effect of solar radiation and regulate external thermal loads thanks to their greater effusivity and thermal capacity. This research compares the thermal behavior of the roofs of two buildings located in Alicante on the Spanish Mediterranean coast: a loft flat in the city center and a water-covered roof in the Museum of the University of Alicante (MUA). Values for effusivity, diffusivity, thermal capacity, decrement factor, time lag and internal, as well as external thermal admittance were obtained. After monitoring both roofs during 2014, behavior simulations were performed in Design Builder using 6 different scenarios reflecting different combinations in both buildings of water-covered, inverted and conventional roofs and marble or terrazzo paving. The water-covered roof led to a higher decrement factor and time lag, as well as to a reduction of annual energy demands between 8.86% and 9.03%.Keywords
Funding Information
- Universidad de Alicante (VIGROB-223)
This publication has 57 references indexed in Scilit:
- Thermal performance of envelope wall/roofs of intermittent air-conditioned roomsApplied Thermal Engineering, 2012
- Dynamic U-value estimation and energy simulation for green roofsEnergy and Buildings, 2012
- LCC and LCCO2 analysis of green roofs in elementary schools with energy saving measuresEnergy and Buildings, 2012
- Thermal dynamic transfer properties of the opaque envelope: Analytical and numerical tools for the assessment of the response to summer outdoor conditionsEnergy and Buildings, 2011
- Monitorización de variables medioambientales y energéticas en la construcción de viviendas protegidas: Edificio Cros-Pirotecnia en SevillaInformes de la Construcción, 2010
- Comparison of experimental and theoretical results for the transient heat flow through multilayer walls and flat roofsEnergy, 2008
- Improving thermal performance of the roof enclosure of heavy construction buildingsApplied Energy, 2008
- Contrasting the capabilities of building energy performance simulation programsBuilding and Environment, 2008
- Thermal performance of building roof elementsBuilding and Environment, 2002
- Transient Conduction in a Fin-Wall Assembly with Harmonic Excitation--Network Thermal AdmittanceHeat Transfer Engineering, 2002