Cytological ROSE diagnosis of pancreatic tumors and tumor-like masses
- 3 August 2023
- journal article
- research article
- Published by Media Sphere Publishing Group in P.A. Herzen Journal of Oncology
- Vol. 12 (4)
Abstract
Objective. To determine the indicators of the diagnostic informative value of cytological rapid on site evaluation (ROSE) study of the material of endoultrasonography (EUS)-guided fine-needle aspiration puncture biopsies (FNAPBs) for the morphological verification of pancreatic masses. Material and methods. The investigation involved the results of 113 cytological ROSE studies of the material of EUS-guided FNAPBs of pancreatic masses, which were conducted at the Department of Endoscopy, P.A. Herzen MORI in 2014 to 2022. For rapid staining of traditional cytological specimens of the material obtained under the guidance of EUS, the investigators used a Leucodif kit (Czechia). In order to clarify the histogenesis of the masses, the authors conducted an immunocytochemical study of 8 (7%) cases in a planned order, by using an Autostainer Link 48 (Dako) on the specimens prepared by liquid-based cytology (CellPrep Plus, Biodyne) or on the same (traditional) glass mold specimens after washing the leucodiff stain if the cellular material was insufficient. The results of the ROSE study were compared with the corresponding pathohistological findings that were available for all the 113 cases. Results. The cytological and histological diagnoses were noted to agree in 107 (93.8%) cases; their disagreement was in 6 (5.3%) cases. Eighty-six (76.1%) and twenty-one (18.6%) cases were interpreted as truly positive and truly negative, respectively. On cytohistological comparison, four (3.6%) and two (1.7%) cases were interpreted as false negative and false positive, respectively. The sensitivity of the cytological study was 95.56% (95% CI, 89.01—98.78); its specificity was 91.30% (95% CI, 71.96—98.93); the diagnostic accuracy was 94.69% (95% CI, 88.80—98.03); the positive predictive value (PPV) was 97.73% (95% CI, 91.95—99.39); the negative predictive value (NPV) was 84.00% (95% CI, 66.64—93.24). Conclusion. The findings of this investigation suggest that the cytological ROSE study of the material of EUS-guided FNAPBs of pancreatic masses.Keywords
This publication has 12 references indexed in Scilit:
- Сytomorphological diagnosis of metastatic lesions to the pancreasPractical oncology, 2020
- Evaluation of endoscopic ultrasound fine-needle aspiration versus fine-needle biopsy and impact of rapid on-site evaluation for pancreatic massesEndoscopy International Open, 2020
- Multicenter, randomized comparison of the diagnostic accuracy of 19‐gauge stainless steel and nitinol‐based needles for endoscopic ultrasound‐guided fine‐needle biopsy of solid pancreatic massesUnited European Gastroenterology Journal, 2020
- This ‘Rose’ Has no Thorns—Diagnostic Utility of ‘Rapid On-Site Evaluation’ (ROSE) in Fine Needle Aspiration CytologyIndian Journal of Surgical Oncology, 2019
- Influence of the Histopathological Features of the Lesion on the Diagnostic Yield of Fine-Needle Aspiration Cytology of Pancreatic Solid LesionsActa Cytologica, 2018
- Endoscopic ultrasound-guided tissue sampling: How can we improve the results?Turkish Journal of Gastroenterology, 2016
- Evaluation of percutaneous ultrasound-guided biopsies of solid mass lesions of the pancreas: a center’s 10-year experienceClinical Imaging, 2015
- Rapid On-site Evaluation of Transbronchial Aspirates in Mediastinal Adenopathy DiagnosisChest, 2011
- Cytopathology of the pancreas: neoplastic and nonneoplastic entitiesAnnals of Diagnostic Pathology, 2010
- Cytologic criteria for well differentiated adenocarcinoma of the pancreas in fine-needle aspiration biopsy specimensCancer, 2002