Development of a Telemetric, Miniaturized Electrochemical Amperometric Analyzer
Open Access
Abstract
In this research, we developed a portable, three-electrode electrochemical amperometric analyzer that can transmit data to a PC or a tablet via Bluetooth communication. We performed experiments using an indium tin oxide (ITO) glass electrode to confirm the performance and reliability of the analyzer. The proposed analyzer uses a current-to-voltage (I/V) converter to convert the current generated by the reduction-oxidation (redox) reaction of the buffer solution to a voltage signal. This signal is then digitized by the processor. The configuration of the power and ground of the printed circuit board (PCB) layer is divided into digital and analog parts to minimize the noise interference of each part. The proposed analyzer occupies an area of 5.9 × 3.25 cm2 with a current resolution of 0.4 nA. A potential of 0~2.1 V can be applied between the working and the counter electrodes. The results of this study showed the accuracy of the proposed analyzer by measuring the Ruthenium(III) chloride ( ) concentration in 10 mM phosphate-buffered saline (PBS) solution with a pH of 7.4. The measured data can be transmitted to a PC or a mobile such as a smartphone or a tablet PC using the included Bluetooth module. The proposed analyzer uses a 3.7 V, 120 mAh lithium polymer battery and can be operated for 60 min when fully charged, including data processing and wireless communication.
Keywords
Funding Information
- Institute for Information and Communications Technology Promotion (2015-0-00390)
This publication has 27 references indexed in Scilit:
- A low-cost miniaturized potentiostat for point-of-care diagnosisBiosensors and Bioelectronics, 2014
- Sensitive and selective trypsin detection using redox cycling in the presence ofl-ascorbic acidThe Analyst, 2014
- Improved sensitivity of point of care troponin I values using reporting to below the 99th percentile of normalsClinical Biochemistry, 2013
- An LTCC-based microfluidic system for label-free, electrochemical detection of cortisolSensors and Actuators B: Chemical, 2013
- Personalized diagnostics and biosensors: a review of the biology and technology needed for personalized medicineCritical Reviews in Biotechnology, 2012
- A highly sensitive electrochemical biosensor based on zinc oxide nanotetrapods for l-lactic acid detectionNanoscale, 2012
- Point-of-care testing (POCT): Current techniques and future perspectivesTrAC Trends in Analytical Chemistry, 2011
- Mechanism of glucose electrochemical oxidation on gold surfaceElectrochimica Acta, 2010
- Microfabricated electrochemical nitrate sensor using double-potential-step chronocoulometrySensors and Actuators B: Chemical, 2009
- A micropower amperometric potentiostatSensors and Actuators B: Chemical, 2004