Glove Reinforcement An Alternative to Double Gloving
Authors:
- Iyad HoushanIHIyad Houshan
- Radhakrishnan SatheesanRSRadhakrishnan Satheesan
- Ramanathan RajuRRRamanathan Raju
- Joseph CunninghamJCJoseph Cunningham
- Anthony AcinapuraAAAnthony Acinapura
- 1 August 2001
- journal article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 22 (8) , 526-527
Abstract
Gloves, worn by the surgical team to prevent transmission of infections from and to patients, are prone to tears and perforations. This study was done to determine the frequency and sites of unrecognized glove perforation during surgical procedures. The percentage of glove perforation was 14%. Of the punctures, 73% occurred in one of four contiguous locations on the glove. We recommend glove reinforcement at these locations to provide better protection, as well as to reduce the burden of double gloving.Keywords
This publication has 4 references indexed in Scilit:
- Comparison of Perforation Between Single and Double‐gloving in Perineorrhaphy After Vaginal Delivery: A Randomized Controlled TrialAustralian and New Zealand Journal of Obstetrics and Gynaecology, 1998
- Loss of Glove Integrity During Emergency Department ProceduresAnnals of Emergency Medicine, 1998
- Detection of glove puncture and skin contamination during caesarean sectionBJOG: An International Journal of Obstetrics & Gynaecology, 1997
- Reducing the risk of viral transmission at operation by electronic monitoring of the surgeon—patient barrierBritish Journal of Surgery, 1994