Reduction of Static Electricity Meter Errors by Broadband Compensation of Voltage and Current Channel Differences
Open Access
- 20 November 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Abstract
To compensate for the different transfer functions of the current and voltage input stages of static electricity meters, usually a time correction is applied, which is suitable for sinusoidal signals. However, for highly-distorted signals, in which the high-frequency content is significant, this method is insufficient and reading errors will not be fully compensated. For such waveforms, this paper describes two alternative methods to deal with the different input stages. The methods are implemented on a home-built waveform recorder, modified as static electricity meter, and validated by means of their influence on energy-reading errors for various waveforms and input stages (impedance and coupling). Apart from highly-distorted current signals, also the effect of finite source impedance is considered by modifying the voltage waveform accordingly, which potentially influences the observed meter errors as well. The inverse-filtering method is the most powerful method but is computationally intensive and, therefore, more suitable for high-accuracy power meters than for inexpensive electricity meters. The less computationally-intensive equivalent-filtering method shows very good results as well and is a better candidate to be implemented in electricity meters. The latter is especially relevant because of recent results showing that some electricity meters are sensitive to specific disturbances beyond the present standard test waveforms.Keywords
Funding Information
- EMPIR Initiative co-funded by the European Union’s Horizon 2020 Research and Innovation Programme
- EMPIR participating states
- Ministerie van Economische Zaken en Klimaat
This publication has 11 references indexed in Scilit:
- Current waveforms of household appliances for advanced meter testing2019
- A Testbed for Static Electricity Meter Testing with Conducted EMI2019
- On-site Waveform Characterization at Static Meters Loaded with Electrical Vehicle Chargers2019
- Sensitivity of static energy meter reading errors to changes in non-sinusoidal load conditions2019
- Conducted EMI Causing Error Readings of Static Electricity Meters2018
- Static energy meter errors caused by conducted electromagnetic interferenceIEEE Electromagnetic Compatibility Magazine, 2016
- Measurements of High-Frequency (2–150 kHz) Distortion in Low-Voltage NetworksIEEE Transactions on Power Delivery, 2010
- On Testing the Electronic Revenue Energy MetersIEEE Transactions on Instrumentation and Measurement, 2009
- Design, Modeling, and Verification of High-Performance AC–DC Current Shunts From Inexpensive ComponentsIEEE Transactions on Instrumentation and Measurement, 2007