This paper presents the experimental dependence of the evaporation rate of a nondeaerated distilled water drop from the heat flux density on the surfaces of non-ferrous metals (copper and brass). A drop was placed on a heated substrate by electronic dosing device. To obtain drop profile we use a shadow optical system; drop symmetry was controlled by a high-speed video camera. It was found that the evaporation rate of a drop on a copper substrate is greater than on a brass. The evaporation rate increases intensively with raising volume of a drop. Calculated values of the heat flux density and the corresponding evaporation rates are presented in this work. The evaporation rate is found to increase intensively on the brass substrate with raising the heat flux density.Keywords
This publication has 6 references indexed in Scilit:
- Effect of surface temperature on spreading rate of liquid dropletMATEC Web of Conferences, 2014
- PrefaceEPJ Web of Conferences, 2014
- Evaporation of a sessile water drop on a heated surface with controlled wettabilityColloids and Surfaces A: Physicochemical and Engineering Aspects, 2014
- The behavior of water droplets on the heated surfaceInternational Journal of Heat and Mass Transfer, 2012
- Thermal effects of the substrate on water droplet evaporationPhysical Review E, 2012
- Evaporation of pure liquid sessile and spherical suspended drops: A reviewAdvances in Colloid and Interface Science, 2012