Outbreak of Pseudomonas aeruginosa producing VIM carbapenemase in an intensive care unit and its termination by implementation of waterless patient care
Authors:
Open Access
- 19 August 2021
- journal article
- research article
- Published by Springer Nature in Critical Care
- Vol. 25 (1) , 1-10
Abstract
Background: Long-term outbreaks of multidrug-resistant Gram-negative bacilli related to hospital-building water systems have been described. However, successful mitigation strategies have rarely been reported. In particular, environmental disinfection or replacement of contaminated equipment usually failed to eradicate environmental sources of Pseudomonas aeruginosa. Methods: We report the investigation and termination of an outbreak of P. aeruginosa producing VIM carbapenemase (PA-VIM) in the adult intensive care unit (ICU) of a Swiss tertiary care hospital with active case finding, environmental sampling and whole genome sequencing (WGS) of patient and environmental strains. We also describe the implemented control strategies and their effectiveness on eradication of the environmental reservoir. Results: Between April 2018 and September 2020, 21 patients became either infected or colonized with a PA-VIM strain. For 16 of them, an acquisition in the ICU was suspected. Among 131 environmental samples collected in the ICU, 13 grew PA-VIM in sink traps and drains. WGS confirmed the epidemiological link between clinical and environmental strains and the monoclonal pattern of the outbreak. After removing sinks from patient rooms and implementation of waterless patient care, no new acquisition was detected in the ICU within 8 months after the intervention. Discussion: Implementation of waterless patient care with removal of the sinks in patient rooms was successful for termination of a PA-VIM ICU outbreak linked to multiple environmental water sources. WGS provides highly discriminatory accuracy to investigate environment-related outbreaks.Keywords
All Related Versions
This publication has 35 references indexed in Scilit:
- A Systematic Review and Meta-Analyses Show that Carbapenem Use and Medical Devices Are the Leading Risk Factors for Carbapenem-Resistant Pseudomonas aeruginosaAntimicrobial Agents and Chemotherapy, 2014
- The role of water in healthcare-associated infectionsCurrent Opinion in Infectious Diseases, 2013
- Pseudomonas aeruginosa Outbreak in a Pediatric Intensive Care Unit Linked to a Humanitarian Organization Residential CenterThe Pediatric Infectious Disease Journal, 2010
- Outbreak of Multidrug-ResistantPseudomonas aeruginosaColonization and Infection Secondary to Imperfect Intensive Care Unit Room DesignInfection Control & Hospital Epidemiology, 2009
- Carbapenemases: the Versatile β-LactamasesClinical Microbiology Reviews, 2007
- Prevention and control of health care–associated waterborne infections in health care facilitiesAmerican Journal of Infection Control, 2005
- The New β-LactamasesNew England Journal of Medicine, 2005
- An Outbreak of Pseudomonas aeruginosa Pneumonia and Bloodstream Infection Associated With Intermittent Otitis Externa in a Healthcare WorkerInfection Control & Hospital Epidemiology, 2004
- Increase in Methicillin-Resistant Staphylococcus aureus Acquisition Rate and Change in Pathogen Pattern Associated with an Outbreak of Severe Acute Respiratory SyndromeClinical Infectious Diseases, 2004
- Hospital outbreak of multiple clones of Pseudomonas aeruginosa carrying the unrelated metallo-beta-lactamase gene variants blaVIM-2 and blaVIM-4Journal of Antimicrobial Chemotherapy, 2003