DETERMINATION OF STRESS CORROSION CRACK INITIATION STRESS AND CRACK VELOCITIES USING SLOWLY STRAINED TAPERED SPECIMENS
Authors:
- 1 November 1989
- journal article
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 12 (6) , 481-493
Abstract
Abstract— Previous work has shown that a single tapered cylindrical specimen subjected to slow strain rate testing can provide data for the crack initiation stress of 70/30 brass in 1N NaNO2 solution. In order to test the wider applicability of that technique, crack initiation stresses of a further five systems were measured. These were 70/30 brass in an ammoniacal solution, copper in sodium nitrite and mild steel in carbonate–bicarbonate, hydroxide or nitrate solutions. The results are compared with those obtained from tests on plain cylindrical specimens subjected to interrupted slow strain rate tests or to constant load tests, and the agreement is reasonable. The method also is capable of providing data on the stress dependence of crack velocities.Keywords
This publication has 9 references indexed in Scilit:
- Localized corrosion and crack initiationMaterials Science and Engineering: A, 1988
- Factors Influencing Stress Corrosion Crack Growth KineticsCorrosion, 1987
- Application of Slow-Strain-Rate Tests to Defining the Stress for Stress Corrosion Crack Initiation in 70/30 Brass1984
- Caustic Stress Corrosion Cracking of Mild SteelMetallurgical Transactions A, 1982
- CORROSION FATIGUE OF MILD STEELS IN A SODIUM NITRATE SOLUTIONFatigue & Fracture of Engineering Materials & Structures, 1982
- Predictive approaches to stress corrosion cracking failureCorrosion Science, 1980
- Report on Activities within the European Federation of Corrosion 1977/78British Corrosion Journal, 1979
- Environment Sensitive Fracture and its PreventionBritish Corrosion Journal, 1979
- The effect of strain-rate upon stress corrosion crack velocity in α-brass in ammoniacal solutionsCorrosion Science, 1979