Identification of under-damped second-order systems using finite duration rectangular pulse inputs
- 1 July 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 834-839
Abstract
This paper uses rectangular pulse inputs of finite duration to identify the parameters of a prototype second-order transfer function. Exact analytical expressions for the damping ratio and the undamped natural frequency are obtained in terms of the time at which the pulse response reaches its maximum value and the maximum value itself. The sensitivity of these expressions to zero mean white noise is studied using variance analysis and Monte Carlo simulations. Our approach compares favorably with existing identification methods both in terms of overall simplicity and user friendliness.Keywords
This publication has 7 references indexed in Scilit:
- Modeling of Hammerstein−Wiener Processes with Special Input Test SignalsIndustrial & Engineering Chemistry Research, 2006
- Step and pulse response methods for identification of wiener processesAIChE Journal, 2005
- Simplified Identification of Time-Delay Systems with Nonzero Initial Conditions from Pulse TestsIndustrial & Engineering Chemistry Research, 2005
- Use of two-stage least-squares algorithms for identification of continuous systems with time delay based on pulse responsesAutomatica, 2004
- Robust identification of continuous systems with dead-time from step responsesAutomatica, 2001
- System Identification1999
- Process Identification Using Pulse Response and Proportional−Integral Derivative Controller Tuning with Combined GuidelinesIndustrial & Engineering Chemistry Research, 1998