Medication Safety in Two Intensive Care Units of a Community Teaching Hospital After Electronic Health Record Implementation: Sociotechnical and Human Factors Engineering Considerations
Authors:
- Pascale CarayonPCPascale Carayon
- Tosha B. WetterneckTWTosha B. Wetterneck
- Roger BrownRBRoger Brown
- Peter HoonakkerPHPeter Hoonakker
- 28 February 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Patient Safety
- Vol. 17 (5) , e429-e439
Abstract
Objective: The aim of the study was to assess the impact of Electronic Health Record (EHR) implementation on medication safety in two intensive care units (ICUs). Methods: Using a prospective pre-post design, we assessed 1254 consecutive admissions to two ICUs before and after an EHR implementation. Each medication event was evaluated with regard to medication error (error type, medication-management stage) and impact on patient (severity of potential or actual harm). Results: We identified 4063 medication-related events either pre-implementation (2074 events) or post-implementation (1989 events). Although the overall potential for harm due to medication errors decreased post-implementation only 2 of the 3 error rates were significantly lower post-implementation. After EHR implementation, we observed reductions in rates of medication errors per admission at the stages of transcription (0.13–0, P < 0.001), dispensing (0.49–0.16, P < 0.001), and administration (0.83–0.56, P = 0.011). Within the ordering stage, 4 error types decreased post-implementation (orders with omitted information, error-prone abbreviations, illegible orders, failure to renew orders) and 4 error types increased post-implementation (orders of wrong drug, orders containing a wrong start or stop time, duplicate orders, orders with inappropriate or wrong information). Within the administration stage, we observed a reduction of late administrations and increases in omitted administrations and incorrect documentation. Conclusions: Electronic Health Record implementation in two ICUs was associated with both improvement and worsening in rates of specific error types. Further safety improvements require a nuanced understanding of how various error types are influenced by the technology and the sociotechnical work system of the technology implementation. Recommendations based on human factors engineering principles are provided for reducing medication errors.Keywords
This publication has 38 references indexed in Scilit:
- Impact of electronic order management on the timeliness of antibiotic administration in critical care patientsInternational Journal of Medical Informatics, 2012
- Factors contributing to an increase in duplicate medication order errors after CPOE implementationJournal of the American Medical Informatics Association, 2011
- A new sociotechnical model for studying health information technology in complex adaptive healthcare systemsQuality and Safety in Health Care, 2010
- The Effect Of Health Information Technology On Quality In U.S. HospitalsHealth Affairs, 2010
- Prescription Errors and Outcomes Related to Inconsistent Information Transmitted Through Computerized Order EntryArchives of internal medicine (1960), 2009
- A Risk Analysis Method to Evaluate the Impact of a Computerized Provider Order Entry System on Patient SafetyJournal of the American Medical Informatics Association, 2008
- Medication-error reporting and pharmacy resident experience during implementation of computerized prescriber order entryAmerican Journal of Health-System Pharmacy, 2007
- Work system design for patient safety: the SEIPS modelQuality and Safety in Health Care, 2006
- Errors Associated With Applying Decision Support by Suggesting Default Doses for AminoglycosidesDrug Safety, 2006
- What is a prescribing error?Quality and Safety in Health Care, 2000