Acoustical Factors of Noise Created by Suctioning Middle Ear Fluid
Authors:
- William J. HenryWHWilliam J. Henry
- Dan F. KonkleDKDan F. Konkle
- 1 July 1993
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 119 (7) , 762-766
Abstract
• Objective. —To quantify the intensity, spectral content, and duration of exposure for suction noise created during aspiration of middle ear fluid following myringotomy. Design. —Case series. Setting. —Tertiary care center. Patients or Other Participants. —Convenience sample of 245 myringotomies performed on 124 patients ranging in age from 6 months to 14 years (mean age, 2 years 8 months). Main Outcome Measures. —Intensity, spectral content, and duration of exposure associated with suction noise were defined by electroacoustic analysis of high-fidelity tape recordings of the noise created during suctioning middle ear fluid. Results. —The intensity of suction noise ranged from 74 to 117 dB; most acoustic energy was concentrated in the frequency range between 1.7 and 6.0 kHz, and the duration of exposure varied from 4 to 23 seconds. (Arch Otolaryngol Head Neck Surg. 1993;119:762-766)Keywords
This publication has 4 references indexed in Scilit:
- Amplification as a Remediation Technique for Children With Normal Peripheral Hearing1991
- Sensorineural Hearing Loss following Chronic Ear SurgeryAnnals of Otology, Rhinology & Laryngology, 1984
- Temporary threshold shifts in humans exposed to octave bands of noise for 16 to 24 hoursThe Journal of the Acoustical Society of America, 1979
- Noise and children: A review of literatureThe Journal of the Acoustical Society of America, 1975