Reliability and Practicality of the Core Score
Authors:
- Rachel BrakkeRBRachel Brakke
- Venu AkuthotaVAVenu Akuthota
- William SullivanWSWilliam Sullivan
- 1 July 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Journal of Sport Medicine
- Vol. 27 (4) , 409-414
Abstract
Pilot study to determine the practicality and inter-rater reliability of the “Core Score,” a composite measure of 4 clinical core stability tests. Repeated measures. Academic hospital physician clinic. 23 healthy volunteers with mean age of 32 years (12 females, 11 males). All subjects performed 4 core stability maneuvers under direct observation from 3 independent physicians in sequence. Inter-rater reliability and time necessary to perform examination. The Core Score scale is 0 to 12, with 12 reflecting the best core stability. The mean composite score of all 4 tests for all subjects was 9.54 (SD, 1.897; range, 4-12). The intraclass correlation coefficients (ICC 1,1) for inter-rater reliability for the composite Core Score and 4 individual tests were 0.68 (Core Score), 0.14 (single-leg squat), 0.40 (supine bridge), 0.69 (side bridge), and 0.46 (prone bridge). The time required for a single examiner to assess a given subject's core stability in all 4 maneuvers averaged 4 minutes (range, 2-6 minutes). Even without specialized equipment, a clinically practical and moderately reliable measure of core stability may be possible. Further research is necessary to optimize this measure for clinical application. Despite the known value of core stability to athletes and patients with low back pain, there is currently no reliable and practical means for rating core stability in a typical office-based practice. This pilot study provides a starting point for future reliability research on clinical core stability assessments.Keywords
This publication has 27 references indexed in Scilit:
- Reliability of Alternative Trunk Endurance Testing Procedures Using Clinician Stabilization Vs. Traditional MethodsJournal of Strength & Conditioning Research, 2010
- Trunk stabilization training: An evidence basis for the current state of affairsJournal of Back and Musculoskeletal Rehabilitation, 2009
- Reliability of clinical tests to evaluate nerve function and mechanosensitivity of the upper limb peripheral nervous systemBMC Musculoskeletal Disorders, 2009
- Core Stability Exercise PrinciplesOptometry and Vision Science, 2008
- Core StabilityOptometry and Vision Science, 2005
- Reliability of Hand-Held Dynamometry in Assessment of Knee Extensor Strength After Hip FractureAmerican Journal of Physical Medicine & Rehabilitation, 2004
- Core Stability Measures as Risk Factors for Lower Extremity Injury in AthletesMedicine & Science in Sports & Exercise, 2004
- Manual strength testing in 14 upper limb musclesA study of inter-rater reliabilityActa Orthopaedica, 2004
- Clinical spinal instability and low back painJournal of Electromyography and Kinesiology, 2003
- Clinical Reliability of Manual Muscle TestingPhysical Therapy, 1987