Ultrathin Descemet Stripping Automated Endothelial Keratoplasty (UT-DSAEK) versus Descemet Membrane Endothelial Keratoplasty (DMEK)—a systematic review and meta-analysis
Open Access
- 18 March 2023
- journal article
- review article
- Published by Springer Nature in Eye
- Vol. 37 (14) , 3026-3032
Abstract
Background/Objectives: Endothelial keratoplasty (EK) is a commonly performed transplant procedure used in the treatment of corneal endothelial dysfunction. The aim of this systematic review and meta-analysis is to evaluate the differences in visual acuity outcomes, endothelial cell density (ECD) and complications between two forms of EK, ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) and Descemet membrane endothelial keratoplasty (DMEK).Methods: A literature search of MEDLINE, Embase and Cochrane Library was conducted to identify studies reporting comparative results of UT-DSAEK versus DMEK. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement was used for search strategy. Of 141 titles, 7 studies met the inclusion criteria; best corrected visual acuity (BCVA) (LogMAR), ECD (cells/mm2), and complications were compared, with all statistical analysis performed using Review Manager.Results: A total of 362 eyes were included for analysis. DMEK resulted in significantly better BCVA at 3 months (0.14 vs 0.22,p = 0.003), 6 months (0.08 vs 0.18,p = 0.005) and 1 year post-op (0.07 vs 0.14,p = 0.0005). UT-DSAEK resulted in significantly lower total complications (25.2% vs 57.3%,p = 0.0001) and rates of re-bubbling (11.0% vs 33.7%,p = 0.004). No differences were found in ECD between the two procedures (1541 vs 1605,p = 0.77).Conclusions: DMEK results in superior visual acuity rates with quicker recovery. However, UT-DSAEK has a more favourable complication profile, particularly regarding lower rates of re-bubbling. Both are valuable options in the treatment of corneal endothelial disease and choice of procedure may depend on surgical expertise.Keywords
All Related Versions
This publication has 49 references indexed in Scilit:
- Does thickness matterCurrent Opinion in Ophthalmology, 2014
- Effects of Graft Thickness and Asymmetry on Visual Gain and Aberrations After Descemet Stripping Automated Endothelial KeratoplastyJAMA Ophthalmology, 2013
- Ultrathin Descemet's Stripping Automated Endothelial Keratoplasty with the Microkeratome Double-Pass TechniqueOphthalmology, 2013
- Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Automated Endothelial KeratoplastyAmerican Journal of Ophthalmology, 2012
- Risk of Corneal Transplant Rejection Significantly Reduced with Descemet's Membrane Endothelial KeratoplastyOphthalmology, 2012
- Learning Curve in Descemet's Membrane Endothelial KeratoplastyOphthalmology, 2011
- Endothelial Keratoplasty for Fuchs' Dystrophy with CataractOphthalmology, 2009
- The Balance between Corneal Transparency and Edema The Proctor LectureInvestigative Ophthalmology & Visual Science, 2006
- Introducing Henry F. Edelhauser, the 2005 Proctor Medal AwardeeInvestigative Ophthalmology & Visual Science, 2006
- Quantifying heterogeneity in a meta‐analysisStatistics in Medicine, 2002