Abstract
We report on the determination of the shear compliance of spin-cast polystyrene films with quartz crystal resonators. The films with a thickness between 10 and 93 nm were sandwiched between the quartz blank and an overlayer of aluminum, which had been evaporated on top of the polymer film in order to enhance the shear stress. The shear compliance was inferred from the frequency shifts on the various overtones. For ease of analysis, the film was placed directly onto the quartz blank with no electrodes underneath, the oscillation being excited externally across an air gap. The derived shear moduli are consistent with the literature values for the bulk material determined from ultrasonic spectroscopy. However, they depend on thickness. For films thicker than 10 nm the apparent compliance decreases with film thickness, which presumably is a consequence of surface roughness. The 10 nm specimen had a much increased compliance, which we attribute to a less dense packing of the polymer chains caused by geometric confinement.

This publication has 11 references indexed in Scilit: