Abstract
Non-contact optical temperature measurement can effectively avoid the disadvantages of traditional contact thermometry and thus, become a hot research topic. Herein, a fluorescence intensity ratio (FIR) thermometry using a time-resolved technique based on La2CaZrO6:Cr3+ (LCZO) is proposed, with a maximum relative sensitivity (Sr − FIR) of 2.56% K−1 at 473 K and a minimum temperature resolution of 0.099 K. Moreover, the relative sensitivity and temperature resolution can be effectively controlled by adjusting the width of the time gate based on the time-resolved technique. Our work provides, to our knowledge, new viewpoints into the development of novel optical thermometers with adjustable relative sensitivity and temperature resolution on an as-needed basis.
Funding Information
  • Central Project Guide local science and technology for development of Hebei Province (226Z1103G)
  • National Natural Science Foundation of China (62075055, 62175075)

This publication has 27 references indexed in Scilit: