Continuous arterial spin labeling at the human common carotid artery: the influence of transit times
Open Access
- 29 September 2004
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 18 (1) , 19-23
Abstract
In evaluating the sensitivity of arterial spin labeling (CASL) and for quantification of perfusion, knowledge of the transit time from the labeling plane to the imaging slice is crucial. The purpose of the current study was to obtain estimates of transit times relevant under the specific experimental conditions of CASL in human subjects using a separate local labeling coil at the neck. Specifically, the post‐label delay (PLD), i.e. the time between the end of the labeling period and the image acquisition, was varied either with or without additional application of crusher gradients to suppress intravascular signal contributions. The overall sensitivity change for varying the PLD between 1000 and 1700 ms was low. A tissue transit time from the neck to an axial supraventricular section through Broca's knee was obtained by fitting the PLD dependence to a two‐compartment model. Averaging over subjects yielded 1930 ± 110 ms for the tissue transit time, and 73 ± 5 ml min−1 100 g−1 for the cerebral blood flow. Small areas that exhibited a very high signal change upon labeling were indicative of regional variation in cerebral blood flow related to vascular anatomy. Copyright © 2004 John Wiley & Sons, Ltd.Keywords
This publication has 21 references indexed in Scilit:
- Efficiency of flow-driven adiabatic spin inversion under realistic experimental conditions: A computer simulationMagnetic Resonance in Medicine, 2004
- Arterial transit time imaging with flow encoding arterial spin tagging (FEAST)Magnetic Resonance in Medicine, 2003
- Functional perfusion imaging using continuous arterial spin labeling with separate labeling and imaging coils at 3 TMagnetic Resonance in Medicine, 2003
- Velocity‐driven adiabatic fast passage for arterial spin labeling: Results from a computer modelMagnetic Resonance in Medicine, 2003
- Continuous arterial spin labeling using a local magnetic field gradient coilMagnetic Resonance in Medicine, 2002
- Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 TeslaMagnetic Resonance in Medicine, 2002
- Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging TechniquesJournal of Cerebral Blood Flow & Metabolism, 1999
- Reduced Transit-Time Sensitivity in Noninvasive Magnetic Resonance Imaging of Human Cerebral Blood FlowJournal of Cerebral Blood Flow & Metabolism, 1996
- MR flow quantification using race: Clinical application to the carotid arteriesJournal of Magnetic Resonance Imaging, 1996
- Perfusion imagingMagnetic Resonance in Medicine, 1992