Initial Accuracy of HIV Rapid Test Kits Stored in Suboptimal Conditions and Validity of Delayed Reading of Oral Fluid Tests
Open Access
- 23 June 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (6) , e0158107
Abstract
To evaluate the effect of storing commonly used rapid diagnostic tests above manufacturer-recommended temperature (at 37°C), and the accuracy of delayed reading of oral fluid kits with relevance to HIV self-testing programmes. A quality assurance study of OraQuick (OraSure), Determine HIV 1/2™ (Alere) and Uni-Gold™ (Recombigen®). Consecutive adults (≥18y) attending Ndirande Health Centre in urban Blantyre, Malawi in January to April 2012 underwent HIV testing with two of each of the three rapid diagnostic test kits stored for 28 days at either 18°C (optimally-stored) or at 37°C (pre-incubated). Used OraQuick test kits were stored in a laboratory for delayed day 1 and subsequent monthly re-reading was undertaken for one year. Of 378 individuals who underwent parallel testing, 5 (1.3%) were dropped from the final analysis due to discordant or missing reference standard results (optimally-stored Determine and Uni-Gold). Compared to the diagnostic reference standard, OraQuick had a sensitivity of 97.2% (95% CI: 93.6–99.6). There were 7 false negative results among all test kits stored at 37°C and three false negatives among optimally stored kits. Excellent agreement between pre-incubated tests and optimally-stored tests with Kappa values of 1.00 for Determine and Uni-Gold; and 0.97 (95% CI: 0.95; 1.00) for OraQuick were observed. There was high visual stability on re-reading of OraQuick, with only 1/375 pre-incubated and 1/371 optimally-stored OraQuick kits changing from the initial result over 12 months. Erroneous results observed during HIV testing in low income settings are likely to be due to factors other than suboptimal storage conditions. Re-reading returned OraQuick kits may offer a convenient and accurate quality assurance approach, including in HIV self-testing programmes.Keywords
Funding Information
- Wellcome Trust (WT091769)
This publication has 11 references indexed in Scilit:
- Uptake, Accuracy, Safety, and Linkage into Care over Two Years of Promoting Annual Self-Testing for HIV in Blantyre, Malawi: A Community-Based Prospective StudyPLOS Medicine, 2015
- Evaluation of HIV testing algorithms in Ethiopia: the role of the tie-breaker algorithm and weakly reacting test lines in contributing to a high rate of false positive HIV diagnosesBMC Infectious Diseases, 2015
- Finger-Stick Whole Blood HIV-1/-2 Home-Use Tests Are More Sensitive than Oral Fluid-Based In-Home HIV TestsPLOS ONE, 2014
- False Positive HIV Diagnoses in Resource Limited Settings: Operational Lessons Learned for HIV ProgrammesPLOS ONE, 2013
- Performance of a Rapid and Simple HIV Testing Algorithm in a Multicenter Phase III Microbicide Clinical TrialClinical and Vaccine Immunology, 2011
- Acute Dengue Fever Causes False-Positive Reactivity in OraQuick Rapid HIV-1/2 Antibody TestJAIDS Journal of Acquired Immune Deficiency Syndromes, 2010
- Sensitivity of Five Rapid HIV Tests on Oral Fluid or Finger-Stick Whole Blood: A Real-Time Comparison in a Healthcare SettingPLOS ONE, 2010
- Field Evaluation of Diagnostic Accuracy of an Oral Fluid Rapid Test for HIV, Tested at Point-of-Service Sites in Rural ZimbabweAIDS Patient Care and STDs, 2009
- Assessing Proficiency of Interpretation of Rapid Human Immunodeficiency Virus Assays in Nonlaboratory Settings: Ensuring Quality of TestingJournal of Clinical Microbiology, 2008
- Post-marketing surveillance of OraQuick whole blood and oral fluid rapid HIV testingAIDS, 2006