Signal Amplification Using “Spot-on-a-Chip” Technology for the Identification of Proteins via MALDI-TOF MS
- 9 December 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 73 (2) , 214-219
Abstract
The presented “spot-on-a-chip” technology enables easy enrichment of samples in the low nanomolar (1−5 nM) range and provides a fast and reliable automated sample preparation method for performing matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analysis with high sensitivity and throughput. Through microdispensing, which allows accurate deposition of 60-pL droplets, dilute samples were enriched by making multiple droplet depositions in nanovials. The sample was confined to a defined spot area (300 × 300 μm), and multiple depositions increase the surface density of analyte in the nanovial, thereby providing detection of low attomole levels. The impact of the nanovial geometry with respect to the MALDI-TOF MS resolution for peptides deposited in the microfabricated silicon vials was investigated and the optimal geometry and size were determined. The spot-on-a-chip technology, that is, the combination of microdispensing, micromachined silicon nanovials and on-spot enrichment provides a signal amplification of at least 10−50 times as compared to an ordinary sample preparation. The linearity of the enrichment effect is shown by the analysis of a peptide mixture at the 5 nM level. The signal amplification provided by the spot-on-a-chip enrichment is demonstrated by the analysis of relevant biological samples, interleukin-8 from a spiked cell supernatant, and by successful protein identification of an excised spot from a high-sensitivity silver-stained two-dimensional electrophoresis gel separation.Keywords
This publication has 17 references indexed in Scilit:
- Capillary liquid chromatography interfaced to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using an on-line coupled piezoelectric flow-through microdispenserJournal of Mass Spectrometry, 2000
- Design and development of a silicon microfabricated flow-through dispenser for on-line picolitre sample handlingJournal of Micromechanics and Microengineering, 1999
- Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide GelsAnalytical Chemistry, 1996
- Polyethylene Membrane as a Sample Support for Direct Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric Analysis of High Mass ProteinsAnalytical Chemistry, 1995
- Improved Resolution and Very High Sensitivity in MALDI TOF of Matrix Surfaces Made by Fast EvaporationAnalytical Chemistry, 1994
- Attomole detection of proteins by matrix‐assisted laser desorption/ionization mass spectrometry with the use of picolitre vialsRapid Communications in Mass Spectrometry, 1994
- Protein identification in DNA databases by peptide mass fingerprintingProtein Science, 1994
- Peptide Mass Maps: A Highly Informative Approach to Protein IdentificationAnalytical Biochemistry, 1993
- Use of mass spectrometric molecular weight information to identify proteins in sequence databasesJournal of Mass Spectrometry, 1993
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988