PITN: Physics-Informed Temporal Networks for Cuffless Blood Pressure Estimation
- 31 October 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Mobile Computing
- Vol. 25 (4) , 4876-4889
Abstract
Estimating blood pressure (BP) plays a crucial role in healthcare. Traditionally, BP has been measured using a cuff, which is unsuitable for continuous BP monitoring. Recent advancements in cuffless wearable devices, such as graphene electronic tattoos and PPG sensors provide viable alternatives. However, existing BP estimation methods often overlook the importance of temporal modeling, despite the multi-periodicity and temporal dependencies inherent in cuffless BP signals. Moreover, continuous BP monitoring requires personalized modeling, which is further challenged by data scarcity. To address these two challenges, we introduce a novel Physics-Informed Temporal Network (PITN) with adversarial contrastive learning to enable precise BP estimation with very limited data for three different modalities (i.e, bioimpedance, PPG, millimeter wave). Specifically, we first introduce a novel Physics-Informed Temporal Network for investigating BP dynamics’ multi-periodicity for cardiovascular cycle modeling and temporal variation. We then apply adversarial training to generate extra physiological time series data, improving PITN’s robustness in the face of sparse subject-specific training data. Furthermore, we utilize contrastive learning to capture the discriminative variations of cardiovascular physiologic phenomena. This approach aggregates physiological signals with similar blood pressure values in latent space while separating clusters of samples with dissimilar blood pressure values. Experiments on three widely-adopted datasets with different modailties demonstrate the superiority and effectiveness of the proposed methods over previous state-of-the-art approaches.Keywords
Funding Information
- National Natural Science Foundation of China (62202063)
- National Natural Science Foundation of China (62572072)
- National Natural Science Foundation of China (62272054)
- National Natural Science Foundation of China (U24B20176)
- National Major Scientific Instruments and Equipments Development Project
- National Natural Science Foundation of China (62427810)
- Natural Science Foundation of Beijing Municipality (L243027)
- Natural Science Foundation of Beijing Municipality (L223002)
- Beijing Nova Program (20230484319)
This publication has 54 references indexed in Scilit:
- Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoringnpj Digital Medicine, 2023
- Continuous cuffless blood pressure monitoring with a wearable ring bioimpedance devicenpj Digital Medicine, 2023
- A benchmark for machine-learning based non-invasive blood pressure estimation using photoplethysmogramScientific Data, 2023
- An efficient hybrid LSTM-ANN joint classification-regression model for PPG based blood pressure monitoringBiomedical Signal Processing and Control, 2023
- Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoosNature Nanotechnology, 2022
- Breaking away from labels: The promise of self-supervised machine learning in intelligent healthPatterns, 2022
- Cuffless blood pressure monitoring from a wristband with calibration-free algorithms for sensing location based on bio-impedance sensor array and autoencoderScientific Reports, 2022
- Deep generative model with domain adversarial training for predicting arterial blood pressure waveform from photoplethysmogram signalBiomedical Signal Processing and Control, 2021
- Physics-informed neural networks: A deep learning framework for solving forward and inverse problems involving nonlinear partial differential equationsJournal of Computational Physics, 2019
- Artificial intelligence in healthcareNature Biomedical Engineering, 2018